3.2 Product description
3.2.1 Data plate

The data plate is located on the product's
PCB and cannot be accessed from the
outside once the product has been moun-
ted on the wall.
The data plate contains the following in-
formation:

Information on the
data plate

Meaning

Serial number

for identification;
7th to 16th digits
= product article
number

VR 91

Product designation

V

Rated voltage

mA

Rated current
Read the instructions

3.2.2 CE marking

The CE marking shows that the products
comply with the basic requirements of the
applicable directives as stated on the de-
claration of conformity.
The declaration of conformity can be
viewed at the manufacturer's site.

3.3 Set-up
3.3.1 Checking the scope of delivery

Quant-
ity

Contents

1

Remote control unit

1

Fastening material (2 bolts and 2
wall plugs)

1

Documentation

3.3.2 Requirements for lines

Use standard commercial lines for the
wiring.

Minimum cross-section:

0.75 mm

²

Maximum line length:

125 m

3.4 Installing the remote control

unit in a living room

1.

Mount the remote control unit on an
interior wall of the main living room
in a position that ensures accurate
measurement of the room temperat-
ure.

Installation height: 1.5 m

Ø6

1

2

1

2

3

1

4

1

Openings for
grommet

2

Mounting open-
ings

3

Pin header with
terminals for the
eBUS line

4

Opening slot

2.

Screw in the wall base in accordance
with the figure.

3.

Connect the eBUS line. (

Page 9)

Summary of Contents for VR 91

Page 1: ...en Operating and installation instructions Remote control unit VR 91 0020200905_02 22 11 2022...

Page 2: ...g 7 2 9 Guarantee and customer service 7 3 For the competent person 7 3 1 Notes on the documentation 7 3 2 Product description 8 3 3 Set up 8 3 4 Installing the remote control unit in a living room 8...

Page 3: ...fe way and understand the hazards in volved Children must not play with the product Cleaning and user maintenance work must not be carried out by children unless they are supervised Any other use that...

Page 4: ...pliance with all inspection and maintenance conditions listed in the instructions Intended use also covers in stallation in accordance with the IP code Any other use that is not spe cified in these in...

Page 5: ...0020200905_02 Operating and installation instructions 5 1 5 Regulations directives laws standards Observe the national regula tions standards directives ordinances and laws...

Page 6: ...alfunctions Ensure that room air can circulate freely around the system control and that the system control is not covered by furniture curtains or other objects Ensure that all thermostatic radiator...

Page 7: ...agents detergents solvents or cleaning agents that contain chlorine 2 8 Decommissioning 2 8 1 Decommissioning the product If you want to replace or remove the product you must decommission the heatin...

Page 8: ...claration of conformity The declaration of conformity can be viewed at the manufacturer s site 3 3 Set up 3 3 1 Checking the scope of delivery Quant ity Contents 1 Remote control unit 1 Fastening mat...

Page 9: ...mponents and the remote control unit start automatically All settings that you have applied using the installation assistant can be changed again at a later date via the level for the end user and com...

Page 10: ...3 9 Resetting to factory setting You can use this function to reset all the set values that you configured using the remote control installation assistant You can access the Reset to default setting f...

Page 11: ...ator 4 Unscrew the wall mounting base from the wall 3 13 Recycling and disposal Packaging Dispose of the packaging correctly This product is an electrical or electronic unit within the context of EU D...

Page 12: ...n be found in the installation instructions for the sys tem control 3 15 Technical data 3 15 1 Remote control unit Rated voltage 9 to 24 V Rated surge voltage 330 V Pollution degree 2 Rated current 50...

Page 13: ...for the system control Setting level Values Unit Increment select Default setting Min Max Information System status System Fault status Current value No fault Fault list Curr room air hum Current valu...

Page 14: ...Saturday Sunday and Monday Fri day Saturday Sunday Monday Sunday Mo Fr 06 00 22 00 Sa 07 30 23 30 Su 07 30 22 00 Period 1 Start End Period 2 Start End Period 3 Start End 00 00 24 00 h min 00 10 Days a...

Page 15: ...ch on all heat generators for approx 1 minute and then switch them on again 2 If the fault persists inform the competent person No changes in the display when the se lection buttons are pressed Softwa...

Page 16: ...ment Set the correct address for the remote con trol unit on the system control in the Zone assignment function System fault Fault in the heating installation Assess the fault messages in the system c...

Page 17: ...20200905_02 Operating and installation instructions 17 Symptom Possible cause Measure Lines appear instead of set and read out values Communication fault 1 Check the plug connection 2 Replace the cabl...

Page 18: ......

Page 19: ......

Page 20: ...isher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 2191 18 0 Fax 49 2191 18 2810 info vaillant de www vaillant de These instructions or parts thereof are protected by copyrigh...

Reviews: