8
Air/flue pipe installation manual 0020308120_02
Optional connection accessories
Article num-
ber
A
B
C, E
D
F
G
H
Extension for variable terminal set (VTK), 60 mm diameter, 1 m,
white
²
303947
X
87° elbow for variable terminal set (VTK), black
²
0020219543
X
X
303944
X
X
87° elbow for variable terminal set (VTK), white
²
0020219544
X
303949
X
45° elbow (2 pcs) for variable terminal set (VTK), black
0020219551
X
X
303945
X
X
45° elbow (2 pcs) for variable terminal set (VTK), white
0020219552
X
303948
X
Deflector set, DN 60, PP, black
0020060584
X
Deflector set, DN 60, PP, white
0020060585
X
1) To reduce the pipe connections that need to be inspected, 4 m extensions are offered on request. (Special delivery with minimum
purchasing quantity. No returns accepted.) The required downward gradient is also 3°. A height of 200 mm is therefore required for the 4
m extension. Take the height into consideration when selecting the installation site.
2) Delivery with pipe clamps
3 In accordance with the construction regulation, installation on the external wall in buildings higher than 18 m (11 m in Scotland) is per-
mitted. The sleeve end of the extension must protrude at least 60 mm from the wall to comply with fire-protection requirements.
3.2
System overview, 80/125 mm diameter
System
group
Article number
Air/flue systems, concentric
A
303200
Vertical roof duct
B
303209
¹
Horizontal wall/roof duct
C
0010035777
²
Horizontal wall duct, stainless steel
D
0010039735
²
External wall connector
E
0020042748
¹
External wall connector
1) In accordance with the construction regulation, installation in buildings higher than 18 m (11 m in Scotland) is not permitted.
2) In accordance with the construction regulation, installation in buildings higher than 18 m (11 m in Scotland) is permitted.
3.2.1
Components
The following table lists the air/flue systems that are permitted as part of the system certification, along with their certified
components.
Optional connection accessories
Article number
A
B, C
D, E
System, concentric, 80/125 mm diameter
Connector (screw holes, 4 x)
303926
X
X
X
Connector with bayonet connection
0020147469
X
X
X
Extension (PP), concentric, 470 mm, 80/125 mm diameter
303202
X
X
X
Extension (stainless steel), concentric, 960 mm, 80/125 mm diameter
¹
0010035778
X
Extension (PP), concentric, 970 mm, 80/125 mm diameter
303203
X
X
X
Extension (PP), concentric, 1970 mm, 80/125 mm diameter
303205
X
X
X
45° elbow (x 2), concentric, 80/125 mm diameter
303211
X
X
X
87° elbow, concentric, 80/125 mm diameter
303210
X
X
X
Pipe clamp (5 pcs), 125 mm diameter
303616
X
X
X
Sliding sleeve, 80/125 mm diameter
303215
X
X
X
Pitched roof tile, black
009076
X
X
Universal pitched roof tile
303980
X
X
Flat roof penetration collar
009056
X
X
System, concentric (stainless steel), 80/125 mm diameter
External wall console, adjustable from 50 to 300 mm, stainless steel
0020042749
X
External wall pipe bracket (stainless steel), 50
–
90 mm
0020042751
X
1 In accordance with the construction regulation, installation on the external wall in buildings higher than 18 m is permitted
Summary of Contents for ecoTEC plus VU Series
Page 1: ...en Air flue pipe installation manual ecoTEC plus VU VUW VUI 0020308120_02 29 09 2022...
Page 57: ......
Page 58: ......
Page 59: ......