Operating instructions

aroSTOR

VWL BM 200/5

VWL BM 270/5

KOsq

Publisher/manufacturer
Vaillant GmbH

Berghauser Str. 40

D-42859 Remscheid

Tel. +492191

18

0

Fax +492191

18

2810

[email protected]

www.vaillant.de

Summary of Contents for aroSTOR VWL BM 200/5

Page 1: ...perating instructions aroSTOR VWL BM 200 5 VWL BM 270 5 KOsq Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 492191 18 0 Fax 492191 18 2810 info vaillant de www vaillant d...

Page 2: ...3 Product description 8 3 1 Product design 8 3 2 Overview of the control elements 8 3 3 Displayed symbols 9 3 4 Type designation and serial number 9 3 5 Information on the data plate 9 3 6 CE marking...

Page 3: ...ndix 16 A Troubleshooting 16 B Optimising energy consumption 17 B 1 Using a low tariff and a control cable connection 17 B 2 Using a low tariff without a control cable connection 18 B 3 Operating with...

Page 4: ...ter generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other install ation components compliance with all inspection and maintena...

Page 5: ...g lighters matches Do not smoke Do not use any electrical switches mains plugs door bells telephones or other communication systems in the building Leave the building immedi ately and ensure that oth...

Page 6: ...igerant circuit as a result of leaks Avoid skin or eye contact with the refrigerant In the event of skin or eye contact with the refrigerant seek medical advice 1 9 Risk of injury and material damage...

Page 7: ...rooms are sufficiently heated You must observe the frost protection instructions 1 13 Avoid environmental damage caused by escaping refrigerant The product contains R 290 refrigerant The refrigerant...

Page 8: ...number aroSTOR VWL BM 200 5 0010026818 aroSTOR VWL BM 270 5 0010026819 3 Product description The product operates at air temperatures between 7 C and 35 C Outside of this temperature range domestic ho...

Page 9: ...VWL Type designation BM Cylinder type 200 270 Cylinder volume 5 Unit version Information on the data plate Meaning COP Coefficient of per formance heating 230 V single phase 50 Hz Voltage and fre quen...

Page 10: ...hat the plugs 1 have been removed from the condensate discharge con nection 2 Ensure that the stopcock upstream of the safety assembly at the cold water inlet is open 3 Before switching on the power s...

Page 11: ...roduct does not automatically switch between summer and winter time You must implement this con version manually Press the button to set the time Press the rotary knob to confirm Turn the rotary knob...

Page 12: ...s energy consumption kWh by programming the operating hours Consider the following points when creating such a programme Electricity tariff tiers low high tariff peri ods Temperature of the drawn in a...

Page 13: ...ys 1 day 24 hour time period the mode will be activated This mode temporarily suspends the set time programming The mode ends automatically once the set number of days has expired Throughout the holid...

Page 14: ...atures below 60 C without consulting the competent person first Contact your competent person in order to have them activate or deactivate the anti legionella function or to find out more information...

Page 15: ...on who installed your product is responsible for the dis posal of the packaging If the product is labelled with this mark In this case do not dispose of the product with the household waste Instead ha...

Page 16: ...energy sources im mersion heater If the air inlet temperature is once again between 7 C or and 35 C the heat pump restarts Time programming conflicts with the high tariff load relief Check the time pr...

Page 17: ...tion B 1 Using a low tariff and a control cable connection Settings made by the end user Setting function Particularly econom ical Average For increased com fort Target temperature 45 C 55 C 65 C Time...

Page 18: ...fort Target temperature 45 C 55 C 65 C Time programming Low tariff LT ECO High tariff HT Frost protection Low tariff LT Comfort High tariff HT up to 12 00 ECO High tariff HT after 12 00 Frost pro tec...

Page 19: ...h a fixed electricity tariff Settings made by the end user Setting function Average For increased com fort Target temperature 45 C 55 C 65 C Time programming From 23 00 to 11 00 Frost protection From...

Page 20: ...ncy The immersion heater can be switched on as required Exception The air temperature lies outside the range between 7 C and 35 C In this case operation of the back up heater is permitted C End user l...

Page 21: ...290841_00 aroSTOR Operating instructions 21 Setting level Values Unit Increment select explana tion Factory set ting Min Max BA CK UP ELEC BACKP ELEC BACKP LAN GUAGE LAN GUAGE 16 available languages E...

Page 22: ......