background image

For the operator 2

0020255239_00 Operating and installation instructions

5

2

For the operator

2.1

Notes on the documentation

2.1.1

Observing other applicable documents

You must observe all operating instructions enclosed with
the system components.

2.1.2

Storing documents

Keep this manual and all other applicable documents
safe for future use.

2.1.3

Validity of the instructions

These instructions apply only to:

Product article number

VEI 300/1 MW

0010023193

VEI 500/1 MW

0010023194

VEI 700/1 MW

0010023195

VEI 800/1 MW

0010023196

VEI 1000/1 MW

0010023197

2.2

Product description

The product is an infrared radiant heater that heats objects
using infrared waves. These warm objects then transfer heat
to their surroundings.

The product is equipped with a safety cut-out that switches
the product off in the event of overheating and switches it
back on automatically once the product has cooled down.

The product should be used in combination with the following
components:

VRT 260f

radio control

Radio receiver

VR 44

radio receiver, exposed

VR 45

radio receiver, concealed

VR 46

remote control socket receiver

VR 48

window-opening detector

The product can be mounted on the wall or ceiling.

Maximum surface temperature at an environmental temper-
ature of 20 °C: 110 °C (115 °C when mounted on the ceil-
ing).

2.2.1

Product design

1

2

3

1

Infrared radiant heater

2

Wall bracket

3

Earthed plug

2.2.2

Data plate

The data plate is located on the back panel of the product.

Information on the
data plate

Meaning

Read the instructions.

VEI

Infrared radiant heater

300 / 500 / 700 / 800
/ 1000

320 / 500 / 650 / 800 / 1000 W nom-
inal heat output (230 V power sup-
ply)

/1

Product generation

MW

Surface material and surface colour
(front)

M = Metal

W = White

1~N PE 230 V

Voltage (V)

Serial number

for identification; 7th to 16th digits =
product article number

2.2.3

CE label

The CE label shows that the products comply with the basic
requirements of the applicable directives as stated on the
identification plate.

The declaration of conformity can be viewed at the manufac-
turer's site.

Summary of Contents for 0010023193

Page 1: ...lation instructions Infrared radiant heater VEI 300 1 MW VEI 1000 1 MW AT DE Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de www vaillant de ...

Page 2: ... Telefon 04621 30 60 89 0 Mail info unidomo com Öffnungszeiten Mo Fr 8 00 17 00 Uhr a member of DAIKIN group Individuelle Beratung Komplettpakete Kostenloser Versand Über 15 Jahre Erfahrung Hochwertige Produkte Markenhersteller ...

Page 3: ... 2 For the operator 5 2 1 Notes on the documentation 5 2 2 Product description 5 2 3 Operation 6 2 4 Troubleshooting 6 2 5 Care 6 2 6 Decommissioning the product 6 2 7 Recycling and disposal 6 2 8 Guarantee and customer service 6 3 For the competent person 7 3 1 Notes on the documentation 7 3 2 Product description 7 3 3 Set up 7 3 4 Installation 9 3 5 Troubleshooting 9 3 6 Decommissioning the prod...

Page 4: ...ere it is normally used Chil dren between the ages of 3 and 8 years must not be allowed to plug the plug into the plug socket adjust the settings on the product clean the product or carry out maintenance work on the product Caution Some parts of the product may become very hot and cause burns Extra care must be taken when children and other vulnerable people are in the vicinity Children must not p...

Page 5: ...Inspection and maintenance Repair Decommissioning Observe all instructions that are included with the product Proceed in accordance with current tech nology Observe all applicable directives stand ards laws and other regulations 1 5 2 Risk of death from electric shock There is a risk of death from electric shock if you touch live components Before commencing work on the product Unplug the mains pl...

Page 6: ... be used in combination with the following components VRT 260f radio control Radio receiver VR 44 radio receiver exposed VR 45 radio receiver concealed VR 46 remote control socket receiver VR 48 window opening detector The product can be mounted on the wall or ceiling Maximum surface temperature at an environmental temper ature of 20 C 110 C 115 C when mounted on the ceil ing 2 2 1 Product design ...

Page 7: ...person who installed your product is re sponsible for the disposal of the packaging If the product is identified with this symbol In this case do not dispose of the product with the household waste Instead hand in the product to a collection centre for old electrical or electronic appliances If the product contains batteries that are marked with this symbol these batteries may contain substances t...

Page 8: ... Maximum surface temperature at an environmental temper ature of 20 C 110 C 115 C when mounted on the ceil ing 3 2 1 CE label The CE label shows that the products comply with the basic requirements of the applicable directives as stated on the identification plate The declaration of conformity can be viewed at the manufac turer s site 3 3 Set up 3 3 1 Checking the scope of delivery Check that the ...

Page 9: ...re that air can circulate continuously between the back panel and the wall or ceiling 3 3 5 Using the mounting template Use the enclosed mounting template to determine the position of the drill holes for mounting the product on the wall or ceiling 3 3 6 Installing the product 1 Drill the holes at the previously marked positions 2 Use suitable rawl plugs hexagon head screws and washers max 4 mm 3 I...

Page 10: ...nk to a VR 44 VR 45 or VR 46 radio receiver 3 5 Troubleshooting 3 5 1 Detecting and rectifying faults Conditions The product is not emitting heat Check the power supply to the product Check whether the product is covered or obstructed 3 6 Decommissioning the product Disconnect the product from the power supply 3 7 Recycling and disposal Disposing of the packaging Dispose of the packaging correctly...

Page 11: ...mm 592 mm Product dimensions depth 17 mm 17 mm 17 mm 17 mm Mains voltage 1 N PE 230 V 1 N PE 230 V 1 N PE 230 V 1 N PE 230 V Nominal heat output 230 V power supply 320 W 500 W 650 W 800 W Permitted air humidity in room 70 70 70 70 Protection class IP 21 IP 21 IP 21 IP 21 VEI 1000 1 MW Net weight 21 5 kg Gross weight 24 kg Product dimensions height 1 500 mm Product dimensions width 750 mm Product d...

Page 12: ......

Page 13: ... Telefon 04621 30 60 89 0 Mail info unidomo com Öffnungszeiten Mo Fr 8 00 17 00 Uhr a member of DAIKIN group Individuelle Beratung Komplettpakete Kostenloser Versand Über 15 Jahre Erfahrung Hochwertige Produkte Markenhersteller ...

Page 14: ...tzbetreiber info vaillant at termin vaillant at www vaillant at www vaillant at werkskundendienst Vaillant Deutschland GmbH Co KG Berghauser Str 40 D 42859 Remscheid Telefon 021 91 18 0 Telefax 021 91 18 2810 Auftragsannahme Vaillant Kundendienst 021 91 5767901 info vaillant de www vaillant de These instructions or parts thereof are protected by copyright and may be reproduced or distributed only ...

Reviews: