KBHF Trouble Shooting Guide
* System Length under 70m, no curves *
**IMPORTANT: Always disconnect and lock out system from mains/power supply
before performing any inspection or installation work **
Layout Guide Lines:
Hanger Placement:
First and Last Hanger
– Must be placed at least 250 mm from end of system with
a max distance of 500mm allowed.
Fix point Hanger
– 1x per system, centered approximately. All other hangers
must be sliding
Distance from joints
– At least 250mm, max distance of 500mm allowed.
Joint Placement :
See installation instruction for step by step
directions.
Joint Cap
– Ensure joint caps are installed
correctly and engaged at top, side and bottom. (see
photo)
Placement
– ensure hangers are placed in
accordance with the minimum distance of 250mm and
max distance of 500mm.