8
Recommendation for protecting devices and cable specification
※
Above data is subject to modification without notice.
N
ote: The above data is adapted to power cord
≤
10 m .If power cord is
>
10 m, wire
diameter must be increased. The signal cable can be extended to 50 m at most.
Trial after first installation
Inspection before connecting power supply
-
Check the installation of the whole machine and the pipe connections according to the
pipe connecting drawing.
-
Check the electric wiring according to the electric wiring diagram, and ground well.
-
Make sure no blockage on the air inlet and outlet, or the efficiency of the heater will be
reduced or cause machine to stop operation.
MODEL
RH(C)25L
RH(C)35L
RH(C)50L
Breaker
Rated Current (A)
15
20
25
Rated Residual Action
Current
(mA)
30
30
30
Fuse char. D (A)
16
20
25
Power Cord
(
mm
2
)
3×2.5
3×2.5
3×4
Signal cable
(
mm
2
)
3×0.5
3×0.5
3×0.5
Always Start
the water pump
before
turning on this machine
Turn off this machine
before
turning off the water pump.
Attention:
Attention: The swimming pool heater must be earthed well.
Summary of Contents for Rapid RH25L