vaetrix ETG Series User Manual Download Page 20

Vaetrix ETG Series User Manual

Units

There are twenty three selectable engineering unit available 

to choose from. In 

Measure Mode

, press the UNITS key and 

use the ARROW keys to scroll through the options. 

Press the UNITS key to accept the selection and the gauge 

will return to 

Measure Mode

.  

If you would like to focus on a couple different engineering 

units or prevent certain users from using an unapproved 

choice for calibration, units can be locked or unlocked under 

Units in 

Program Mode

Use the right or left ARROW keys to highlight LOCK, SCROLL, 

or UNLOCK. Use the up or down ARROW keys to either 

LOCK, SCROLL, or UNLOCK the engineering units, depending 

on which function is highlighted. 

2/19/2019

20

Summary of Contents for ETG Series

Page 1: ...factured in the USA The gauge itself is backed by an industry leading four year warranty Our products are designed and built to take abuse We would have it no other way The only way we can get better is by listening to you the customer If you have any comments or suggestions feel free to send us an email at sales vaetrix com or call at 888 797 3740 Brief Overview The gauge is powered by 3 AA alkal...

Page 2: ... Measure Mode There are two modes of operation Measure The Measure Mode keys ZERO UNITS and SNAPSHOT are active The backlight will automatically turn On with any key press and remain on for 60 seconds Backlight settings can be changed in Program Mode under DISPLAY Program Simply press and hold the DOWN arrow to access Program Mode Use the ARROW keys to navigate and SELECT to confirm The quick over...

Page 3: ...ry Calibration ALARMS On Off Set High or Low BARGRAPH On Off CLOCK Set Date Time Time Zone and Format DAMPING On Off DATALOGGING Start Configure DISPLAY Timeouts Contrast Refresh Interval Color LEAKTEST Start Stop MINMAX Reset SENSOR Gauge or Absolute SNAPSHOT View TARE Live Offset Reset UNITS Lock Scroll Unlock 2 19 2019 3 ...

Page 4: ... stripping and provide adequate sealing Use backup wrench on pressure sensor to install or remove fitting Gauge is not approved for use in hazardous locations To clean the gauge wipe down with damp cloth and small amount of dish soap Do not submerge the unit in water at anytime 2 19 2019 4 Symbol Description Power Off Power On Earth Ground Warning Risk of Danger or Damage European Conformity Hazar...

Page 5: ...ain access to these features The default password is 2017 Use the ARROW keys enter in the value and press the SELECT key Admin Control Features The menu options in the gauge can locked out according to your preferences SCROLL using the up or down ARROW keys to highlight the options Use the right or left ARROW keys to LOCK or UNLOCK The end user will enter password to UNLOCK 2 19 2019 5 ...

Page 6: ...k in Admin and selecting INCREASE RESOLUTION Admin Adjust Calibration We recommend calibration on an annual basis Calibration frequency should be determined by your quality system based on history usage and other key criteria Although we suggest you return the ETG to factory for calibration you can field calibrate the unit with trained personnel and equipment traceable to the National Institute of...

Page 7: ...reference setpoint Once again we recommend you are with 10 of the setpoint Admin Adjust Calibration The unit will respond by with Storing Calibration and return to Measure Mode Certain pressure ranges may have more than two pressure reference setpoints Follow the same procedure of entering in the known value and confirming with SELECT key Once the calibration is complete verify the gauge is within...

Page 8: ...on process or the gauge is not within specification the factory defaults can be restored Navigate to RESTORE FACTORY CAL and press the SELECT key The unit will respond by with Storing Calibration and return to Measure Mode Contact the factory if you are having any issues with calibration 2 19 2019 8 ...

Page 9: ...and then SET To set the alarm value use the right or left arrow keys to select the decimal place and the up and down are keys increase or decrease the value Press SELECT to confirm the value and return to the selection menu Once the alarm setpoint has been reached the high or low alarm icon will show on the display and background color will change to red to indicate an alarm status To disable an a...

Page 10: ...value from 0 to 100 based on the pressure range of the gauge purchased It is an excellent reference tool to remind the end user of the safe working pressure and is broken down into ten segments If you prefer not to use the bar graph it can be turned OFF by using the RIGHT arrow key and pressing SELECT 2 19 2019 10 ...

Page 11: ...s The unit will keep time even when the standard AA batteries are replaced To set the Date Time Time Zone Daylight saving time or Time Format use the ARROW keys to highlight the choice and press SELECT Make sure that gauge is set to match the PC to avoid any synching issues with time when uploading or downloading data 2 19 2019 11 ...

Page 12: ...readings in up to 200 unique sessions in the internal non volatile memory In datalogging mode the current sample rate and how many hours the gauge can record before the memory is at capacity is shown At Low Battery Indication the unit will shut down the datalogging feature To change settings select CONFIGURE The sample rate can be set from 1 second to 24 hours Just use the arrows key to desired va...

Page 13: ...ly choose START ON ALARM and press SELECT Datalogging will start based on either the High or Low alarm setting and run at the defined interval from that point forward Clearing the alarm will not turn off Datalogging DELETE ALL DATA will erase all the logged data on the unit Use the UP arrow key or HOME to escape 2 19 2019 13 ...

Page 14: ...t choose SET and press SELECT to define the interval Use the left or right arrow keys to move the cursor and up and down arrow keys to set the value Press SELECT to confirm the value The status in the menu will change from INACTIVE to ACTIVE denoting the current state Certain lighting conditions may require an adjustment to the display contrast for optimum viewing Use the Up and Down arrow keys an...

Page 15: ...graphics display is updated can be set to the user s preference The default setting for the gauge is REALTIME This means the gauge updates up to 4 times a second depending on loading If a high update rate is not needed the interval can be extended to conserve battery life To adjust the refresh intervals in seconds use the Arrow Keys and press SELECT The interval can be set to a maximum of thirty s...

Page 16: ...leak rate in units minute In addition the results with start time and end time are displayed until the next test is started Minimum test time is 10 seconds To start a new test use the left arrow key Min Max The ETG tracks the Maximum and Minimum pressure readings from the time the unit powers on or the data was last reset MAX MIN and LIVE pressure readings can be viewed all on one screen Just choo...

Page 17: ...fect vacuum so it s equal the sum of Gauge pressure and Atmospheric pressure Gauge pressure is always referenced to atmosphere It is always crucial to perform a zero before attempting a calibration to eliminate any errors that may be caused by fluctuating pressure or changing conditions Just make your choice and press the SELECT key The engineering unit chosen will be followed with A absolute or G...

Page 18: ...re Mode Just press right arrow key and you will notice the camera icon appearing for one second to note a picture was taken with a date and time snap Up to twenty snapshots can be taken and stored To view the pictures select SNAPSHOT in program mode Use the Up and Down arrow to scroll through the readings The date and time is stored with each snapshot Any new snapshots taken will overwrite the old...

Page 19: ... Applications where existing pressure can t be removed and must be accounted for are perfect for the tare feature For example measuring level in tank based on hydrostatic pressure using a dead leg Manual tare values can be set by selecting OFFSET Tare is indicated in Measure Mode when applied 2 19 2019 19 ...

Page 20: ...nd the gauge will return to Measure Mode If you would like to focus on a couple different engineering units or prevent certain users from using an unapproved choice for calibration units can be locked or unlocked under Units in Program Mode Use the right or left ARROW keys to highlight LOCK SCROLL or UNLOCK Use the up or down ARROW keys to either LOCK SCROLL or UNLOCK the engineering units dependi...

Page 21: ...e is more than one gauge connected to the PC the SN will appear in the dropdown selection To start a new session simply use the slider bar or type in value to set the logging interval from one second to twenty four hours and the press the Start New Session button A session can be ended at any time by clicking Stop Session If the High or Low Alarm values are enabled in the ETG datalogging can be st...

Page 22: ...u would like to save in the default directory or any location you would like to choose The software will confirm the files are saved with a pop up box The software will bring the data in using the engineering unit that is selected on the gauge when the session was started There is the option to change the engineering units by using the dropdown menu 2 19 2019 22 ...

Page 23: ...h two tabs Report and Data The Data tab will provide the raw data with the gauge information settings and date time stamp The Report tab will bring the data in using a preformatted report with graphing function Individual datapoints can be displayed by hovering the mouse or pointer device on the graph 2 19 2019 23 ...

Page 24: ...mm high Protected with Polycarbonate Positive Pressure Accuracy 0 05 Full Scale 0 1 Full Scale or 0 25 Full Scale See range options for details Vacuum Accuracy 0 25 Full Scale Applies to pressure range of 500 psi and below with an isolated sensor All units will read vacuum They are not to be used in a continuous vacuum below 14 psi with the exception of the compound sensors Barometric Accuracy 0 3...

Page 25: ...ront Low Battery Indication 3 7 Volts 3 5 Volts Shutdown Battery Life Typical Use Duracell Ultra 1000 Hours Backlight On in Measure Mode 1500 Hours No Display Datalogging at 1 Second Interval Memory Non Volatile Flash Memory 64000 Samples 200 Sessions Output USB MICRO B Fitting MNPT Over Pressure 120 Native Full Scale Range Display indicates Over Range Burst Pressure 3X Native Full Scale on Most R...

Page 26: ...ate 4 Readings Per Second Units 23 Selectable 1 Custom Bluetooth Optional BLE Low Energy Registered Under FCC WAP2001 Warranty 4 Years Register product at www vaetrix com 2 19 2019 26 1 92 48 8 5 95 151 1 1 65 41 9 4 08 103 6 ...

Page 27: ...Specifications Panel Mount Power 5 Volts USB Micro B 50 60 Hz 100V 240V AC Adapter Provided Dimensions 5 26 Outer Diameter x 4 08 Inner Diameter x 3 1 Depth Weight 1 7 Pounds 771 Grams 2 19 2019 27 ...

Page 28: ...e with 316SS 100 12 to 100 I 3x L Gas and Liquids compatible with 316SS 300 12 to 300 I 3x L Gas and Liquids compatible with 316SS 500 12 to 500 I 3x L Gas and Liquids compatible with 316SS 1K 0 to 1000 I 3x L Gas and Liquids compatible with 316SS 3K 0 to 3000 I 3x L Gas and Liquids compatible with 316SS 5K 0 to 5000 I 3x L Gas and Liquids compatible with 316SS 10K 0 to 10000 I 2x L Gas and Liquid...

Page 29: ...L Gas and Liquids compatible with 316SS 500 12 to 500 I 2x L Gas and Liquids compatible with 316SS 1000 0 to 1000 I 2x L Gas and Liquids compatible with 316SS 3K 0 to 3000 I 2x L Gas and Liquids compatible with 316SS 5K 0 to 5000 I 1 5x L Gas and Liquids compatible with 316SS 10K 0 to 10000 I 1 5x L Gas and Liquids compatible with 316SS 14 5K 0 to 14500 I 1 5x L Gas and Liquids compatible with 316...

Page 30: ...ount 15 30 100 300 500 1000 3000 5000 10000 I Isolated C Compound 05 0 05 Full Scale BT Bluetooth BLE EX Intrinsically Safe Pending ETG Portable Handheld 5 30 100 500 1000 3000 5000 10000 14500 I Isolated 10 0 1 Full Scale 25 0 25 Full Scale BT Bluetooth BLE EX Intrinsically Safe Pending 2 19 2019 30 ...

Page 31: ... 21093 20 001 69 001 67 001 61 001 1551 1 206 01 0 2001 1551 1 100 100 01 6 0001 6894 1 7 0001 2768 1 7030 1 70309 68 001 230 01 224 01 203 01 5171 1 689 01 0 6001 5171 1 300 300 01 20 001 20684 21 001 8304 1 21093 205 01 692 01 673 01 610 01 15515 2068 1 2 0001 15515 500 500 01 34 001 34474 35 001 13840 35154 341 01 1153 1 1121 01 1018 01 25858 3447 1 3 0001 25858 1000 1000 1 68 001 68948 70 001 ...

Page 32: ...od of forty eight months from the date of shipment to the original buyer If you fail to register the product a limited twelve month warranty will remain in effect Vaetrix will repair or replace any defective device at no charge this includes shipping charges All warranty claims will be evaluated to determine if the claim was caused by product alteration misuse or use outside the published specific...

Reviews: