vaetrix e Gauge 1 Operation Manual Download Page 1

SINCE

1958

OPERATION MANUAL 

for

Vaetrix PLOT Application,

 

e

Gauge 1

&

 

e

Gauge 3

Summary of Contents for e Gauge 1

Page 1: ...SINCE1958 OPERATION MANUAL for Vaetrix PLOT Application eGauge 1 eGauge 3...

Page 2: ...ric Pressure 10 Status Indicators 10 Low Battery Indicator 10 Error Codes 10 Communication 11 Changing the Batteries 11 Recalibration 11 Applications 13 Product Specifications 15 Troubleshooting 17 Er...

Page 3: ...housed in aluminum bodies and will be hereafter referred to as eGauge A MIN MAX function captures the extremes of varying pressure signals The data logging function allows the capability to pause chan...

Page 4: ...pdate Rate When MENUS is displayed two menus are displayed as the screen below shows The two menu s available are Pressure Units Enabled and the Gauge Update Rate To select a menu use the NEXT and PRE...

Page 5: ...the process the gauge is The display will briefly indicate the full scale pressure of installed transducer serial number date of last calibration current date and time and the barometric pressure rea...

Page 6: ...ions are defined depending on the operating mode of the eGauge and are shown on the display above each key ON OFF Button has one function and purpose to turn the eGauge on or off When the eGauge is tu...

Page 7: ...t temperature are monitored in real time the display is updated four times per second 2 Fluid temperature is acquired through the RTD every 30 seconds and the display is updated at the time of acquisi...

Page 8: ...be changed before logging starts 1 Txxx SEC is the time interval between samples The xxx is the number of seconds between samples 2 START button will start the logging process 3 GAUGE button will sto...

Page 9: ...ensure enough storage space is available when gauge is logging Static pressure measurement is taken from the transducer mounted in the eGauge This very special transducer is the only repairable press...

Page 10: ...ric transmitter If the port is obstructed DO NOT attempt to clear with high pressure air Blowing into the barometric vent will cause damage to the transmitter When cleaning the eGauge take special car...

Page 11: ...se to open the battery compartment The cover is hinged at the bottom and should swing open freely Remove the batteries from the holders eGauge1 On replacing the batteries in the eGauge1 use a Phillips...

Page 12: ...ed to be adjusted to the dead weight test units 4 Verify the system has NO LEAKS 5 Effect of system head is corrected by theAUTO ZERO function of the eGauge The evaluation performed will confirm calib...

Page 13: ...ssure gauges transmitters or static pressure on chart recording systems The system will accept the use of hydraulic fluid distilled water or air dependent on type of stable pressure source used Althou...

Page 14: ...ystem for the calibration of differential transmitters and gauges The system will accept the use of hydraulic fluid distilled water or air dependent on type of stable pressure source used Note The low...

Page 15: ...onlinearity hysteresis repeatability and temperature effects on both span and zero drift for pressures greater than 10 of Full Scale For pressures 1 to 10 of Full Scale the accuracy is 02 of Full Scal...

Page 16: ...inless Steel Optional For use with fluid compatible with Inconel X750 Stainless Steel CONNECTION Pressure 1 4 MNPT up to 10 000 PSI 1 4 High pressure autoclave up to 50 000 PSI Temperature 1 2 Thermo...

Page 17: ...iminish as the gas dissolves into the fluid t Solution Evacuate all tubing with a vacuum pump before introducing fluid into the system Non repeatability of Pressure Measurements When checking the gaug...

Page 18: ...ult factory Readings are not correct Reason Batteries are bad t Solution Replace all 4 AA Batteries After Replacing Batteries readings are still not correct t Solution Check gauge against standard tha...

Page 19: ...ients have been corrupted in any way Err 05 is displayed t Solution Non Field repairable consult factory Err LB Displayed Reason Low Battery t Solution Need to replace Batteries Err AD Displayed Reaso...

Page 20: ...adjust settings in the eGauge1 or eGauge3 Blue tooth SETUP The user will need to pair the eGauge Blue tooth with the PC Blue tooth This can be done through a Blue tooth wizard The following steps desc...

Page 21: ...aph Customer Data This item is enabled when a log file has been opened It will allow the user to incorporate User s data into the graph s cover page The user also has the capability to define 3 fields...

Page 22: ...s feature is used to maximize battery life This function is automatically disabled in the Log Mode The DAMPING function can be enabled or disabled If there is check mark beside Damping then it is enab...

Page 23: ...23 NOTES...

Page 24: ...For technical support concerning the operation of the Vaetrix PLOT contact our Vaetrix Brand Department at Email sales vaetrix com CONTACT FOR TECHNICAL SUPPORT AND SERVICE...

Reviews: