The light in the camera's base indicates its current state.
n
Blue – Camera is active
n
Purple – Standby mode or booting
n
Yellow – Firmware update is in progress
n
Blinking blue – USB cable is disconnected (UC color scheme)
n
Blinking red – Video mute is on (UC color scheme)
Caution
Do not remove power or reset the camera while the indicator is yellow, showing a firmware update in
progress. Interrupting a firmware update can make the camera unusable.
Note
By default, the camera's status light is active during normal operation; however, it can be configured to
remain off when the camera is powered up. The camera may be sending video even if the indicator light is
off.
Restoring Default Camera Settings
Factory reset clears most settings and returns soft DIP switches (on the DIP Switches tab of the System
page) to their default positions.
Using the switches on the back of the camera:
Set all DIP switches DOWN and cycle the power to
reload the default camera settings. Then return all DIP switches to the desired settings.
From the web interface:
Log on using the admin account, go to the System page's Firmware tab, and
select Restore Factory Settings.