Basic Camera Settings – RoboSHOT 12E USB and RoboSHOT 30E USB
S
YSTEM PAGE
, DIP S
WITCHES TAB
Basic settings for the RoboSHOT E-series cameras are on the lower row of soft DIP switches. These
correspond to the physical switches on the older RoboSHOT 12 USB cameras.
IR Frequency Selection:
If there are multiple cameras in the room, use
switches 1 and 2
to configure
each with a different IR frequency to allow the IR Remote Commander to control them independently. Then
use the Camera Select buttons at the top of the remote to select the camera you want to control.
n
SW1 and SW2 up: IR frequency 1
n
SW1 down, SW2 up: IR frequency 2
n
SW1 up, SW2 down: IR frequency 3
IR:
Leave
switch 3
in the default UP position if the IR remote will be used.
Image Flip:
If mounting the camera upside-down, set
switch 4
to the DOWN position: IMAGE FLIP ON.
Baud:
Set
switch 6
to the baud rate of the device connected to the RS-232 port. The default is 9600 bps.
The 38400 baud setting is optional if the connected control device supports it.
HDMI Color:
Set the color space for the HDMI output to YCbCr (default; switch 7 UP) or sRGB.
52