![VADDIO RoboSHOT HD-SDI Series Complete Manual Download Page 61](http://html1.mh-extra.com/html/vaddio/roboshot-hd-sdi-series/roboshot-hd-sdi-series_complete-manual_3321677061.webp)
Basic Camera Settings for RoboSHOT 12E SDI and
RoboSHOT 30E SDI
S
YSTEM PAGE
, DIP S
WITCHES TAB
Basic settings for the RoboSHOT E-series cameras are on the lower row of soft DIP switches. These
correspond to the physical switches on the older RoboSHOT cameras.
IR1, IR2, IR3 (Frequency Selection):
If there are multiple cameras in the room, use these two switches
to configure each camera with a different IR frequency. Then use the Camera Select buttons at the top of
the remote to select the camera you want to control. This allows the IR Remote Commander to control
them independently.
n
Left and right IR switches up: IR frequency 1
n
Left IR switch down, right IR switch up: IR frequency 2
n
Left IR switch up, right IR switch down: IR frequency 3
IR On/Off:
Leave this switch UP if the IR remote will be used.
Image Flip:
If mounting the camera upside-down, set the Image Flip switch ON. The video image will
display right side up, and the tilt controls will behave as expected.
Baud Rate:
Set this switch to match the baud rate of the device connected to the RS-232 port.
HDMI color:
YCbCr (default) or sRGB.
56