AutoTrak 2.0 Camera Tracking System
AutoTrak 2.0 Camera Tracking System - Document Number 342-0382 Rev. E Page 13 of 52
4)
GPIO Port:
The GPIO Port provides the ability to interface with external control systems. Inputs
are logic level low. Output is an open collector.
Pin
Function
1
Power (12 VDC)
2
Mute Toggle (Input)
3
Mute Status (Output)
4
Volume Up (Input)
5
Volume Down (Output)
6
Not Used
7
Ground
5)
USB Type B Connector:
This connector is used to interface with the Host PC for soft-client
codec type applications.
6)
Audio Outputs:
There are two (2) Audio Outputs on the rear panel:
Balanced Audio Output Jack:
Balanced Line Level (on XLR - M connector) +4dBu
Unbalanced Audio Output Jack:
Unbalanced Line Level (on RCA-F connector)
-10dbV
Pairing Procedure for Belt Pack Pairing with the AutoTrak 2.0 Wireless Audio Interface:
A.
Place the Belt Pack in close proximity to the AutoTrak 2.0 Wireless Audio Interface.
B.
Remove the Battery Compartment Cover: To open: See top of page 9.
C.
Locate Pairing Button Switch labeled SW3. Press the button and release. The Radio LED on the
Belt Pack will begin blinking at a slow rate.
Important Note:
The Pairing button on the AutoTrak 2.0 Wireless Audio Interface must
be pushed within ten (10) seconds of pressing the pairing button SW3 on the Belt Pack or
pairing will not occur!
D.
Press the Pair Button on the front panel of the EasyTalk AutoTrak 2.0 Wireless Audio Interface.
E.
The Belt Pack and the AutoTrak 2.0 Wireless Audio Interface will automatically sync with each
other.
The blue Radio LED’s on the Belt Pack and the AutoTrak 2.0 Wireless Interface will
illuminate solid blue indicating they are paired and ready for operation.
Lanyard, Belt Pack Controls:
The central medallion of the lanyard has an attached, strain-relieved, 32” cable
that terminates to a 5-pin mini XLR female connector. Attach the 5-pin mini XLR
to the 5-pin mini XLR male connector on the belt pack. The microphone element
is on the top of the central medallion. The lanyard material houses a flat flex type
circuit where the IR LEDs are mounted. After the initial setup is complete, the
presenter should slip the lanyard over their head and position the medallion away
from the presenter and face the Vaddio logos on the lanyard cloth cover out,
toward the cameras. Clip the belt pack onto the clothing, belt or waistband
securely.
Please avoid dropping the belt pack!
A smashed Belt Pack isn’t a
happy thing. However, replacements are available.
Power to illuminate the IR LEDs is supplied from the Belt Pack and if the System
Power Switch is ON, the IR LEDs will illuminate at 850 nanometers (out of the
range of visible light for mere humans). Each Lanyard has 15 IR LEDs spread
out evenly throughout the Lanyard Necklace. This invisible light is picked up by
the IR reference camera of the AutoTrak 2.0 System and information is sent to
the Tracking Camera in order to follow the presenter throughout the presentation
environment.
Central
Medallion
32” Cable to
Belt Pack
Mic
Element
24”
Lanyard
Necklace
AutoTrak 2.0 Belt
Pack and Lanyard
Belt Pack
Note: Do not fold the Lanyard Necklace at any time as it contains a
flexible circuit that may cease to work if the necklace is hard folded.