General information

Read this manual carefully before installing or operating the equipment. 

Observe the instructions contained in this manual.

+

 

Read the manuals of the rotary vane pump and of the diffusion 

pump before installing or operating the equipment. Observe 

the instructions contained in those manuals.

+

  Do not use any damaged equipment. 

•  Use the handles when moving the pump.

Remove all packing material from the packing box. Remove the product from its 

packing-box and retain all packaging until the equipment is inspected and tested. 

Remove the protective caps from the inlet and outlet ports and retain for future use. 

Inspect the equipment promptly and carefully.

If the equipment is damaged, notify the supplier and the carrier in writing within 

three days. Retain all packing material for inspection. State the item number of the 

product together with the order number and the supplier’s invoice number. Failure 

to check and give notice of damage will void any and all warranty claims for those 

deficiencies.

Replace the protective caps, if the equipment is not used immediately. Store the 

equipment in dry and non-corrosive conditions.

Intended use

+

  Do not use the pump or any system parts on humans or animals.

+

  Ensure that the individual components are only connected, combined and oper-

ated according to their design and as indicated in the instructions for use. 

  Use only 

original manufacturer’s spare parts and accessories

. Otherwise the 

safety and performance of the equipment, as well as the electromagnetic com-

patibility of the equipment might be reduced.

  The CE mark may be voided if not using original manufacturer’s spare parts.

+

  Comply with all notes on correct vacuum and  electrical connections; see section 

“Use and operation“.

+

 The pumps are designed for 

ambient temperatures

 during operation between 

+12°C and +40°C. Periodically check maximum temperatures if installing the 

pump in a cabinet or a housing. Make sure ventilation is adequate to maintain 

recommended operating temperature. Install an external automatic ventilation 

system if necessary. If pumping hot process gases, make sure that the maximum 

permitted gas inlet temperature is not exceeded. The maximum permitted gas 

inlet temperature depends on several parameters like inlet pressure and ambient 

temperature (see ”Technical Data”).

Particles and dust must not enter the pump. 

Do not pump liquids.

Use the equipment 

only as intended

, that is, for generation of vacuum in vessels 

designed for that purpose. Any other use will automatically invalidate all warranty 

and liability claims. Remain aware of safety and risks.

NOTICE

NOTICE

Summary of Contents for HP 40B2

Page 1: ...completely and unchanged It is strictly the users responsibility to check carefully the validity of this document with respect to his product Manual no 999069 28 04 2016 Technology for Vacuum Systems...

Page 2: ...sted intensively including an endurance run of 24 hours Any faults even those which occur rarely are identified and can be eliminated immediately After completion of the endurance run every pumping un...

Page 3: ...and operation 14 Setting up and installing 14 Getting started 14 During operation 15 Shutdown 16 Accessories 16 Troubleshooting 16 Maintenance 16 Repair Maintenance Return Calibration 17 EC Declaratio...

Page 4: ...immediately Store the equipment in dry and non corrosive conditions Intended use Do not use the pump or any system parts on humans or animals Ensure that the individual components are only connected c...

Page 5: ...Do not operate the pump with overpressure at the inlet Avoid overpressure of more than 1 2 bar absolute in the event that inert gas is connected to the pump to the gas ballast or to a venting valve N...

Page 6: ...ons and guidelines Implement the required actions and adopt suitable safety mea sures Ambient conditions Adopt suitable measures in case of differences from recommended conditions e g using the equipm...

Page 7: ...bstances from the pump outlet install an appropriate collecting and disposal system and take protective action for pump and environment You must take suitable precautions to prevent any formation of e...

Page 8: ...ssary Attention If the maximum permissible inlet pressure or the backing pressure at the diffusion pump are exceeded pump fluid might enter other parts of the vacuum system Provide appropriate protect...

Page 9: ...Use appropriate protective clothing safe ty goggles and protective gloves Wear parts have to be replaced regularly Never operate a defective or damaged pump Vent the pumping unit before starting maint...

Page 10: ...ump Pump fluid capacity of diffusion pump ml 30 Maximum pumping speed l s 22 37 Ultimate vacuum mbar 1 x 10 6 Maximum permissible inlet outlet pressure absolute bar 1 1 Maximum pressure difference bet...

Page 11: ...ffusion pump AX 65 2 Backing pump RZ 2 5 3 Backing pump RZ 6 4 ON OFF switch diffusion pump 5 ON OFF switch backing pump 6 Rating plate of pumping unit 7 Connection diagram 8 Handle Position Component...

Page 12: ...idity of this document with respect to his product Manual no 999069 28 04 2016 An oil mist filter for installation at the outlet of the rotary vane pump RZ 6 is separately packed Pay attention to the...

Page 13: ...be used and distributed completely and unchanged It is strictly the users responsibility to check carefully the validity of this document with respect to his product Manual no 999069 28 04 2016 HP 63B...

Page 14: ...matic ventilation system Use connecting hoses with large diameter and keep them as short as possible to avoid flow losses Locate the pump as closely as possible to the application Always install outle...

Page 15: ...V2 once the pressure inside the vacuum vessel is below 0 1 mbar Open fore vacuum valve V1 Open high vacuum valve V3 Note If the fore vacuum M1 rises above 0 1 mbar close the high vacuum valve V3 and p...

Page 16: ...e diffusion pump Proceeding in accordance with the instructions given above ensures that the diffu sion pump is kept under vacuum no condensate build up in the pump fluid To avoid possible formation o...

Page 17: ...t are no original components Drain the device completely of fluids and residues Decontaminate the device Close all openings airtight especially if using substances hazardous to health To expedite repa...

Page 18: ...ed for service staff 11 If the paint is damaged we wish a repaint or a replacement of parts for reason of appearance repaint and replacement at customer s expense yes no 12 Legally binding declaration...

Page 19: ...de pompage Typ Type Type HP 40B2 HP 63B2 Artikelnummer Order number Num ro d article 699029 2612089 699037 Seriennummer Serial number Num ro de s rie Siehe Typenschild See rating plate Voir plaque si...

Page 20: ...lts obtained under test conditions for specific applications depend on a number of factors beyond our control It is therefore strictly the users responsibility to very carefully check the validity of...

Reviews: