VACUTEC Leakfinder 625-WV609 Instruction Manual Download Page 1

 

 

INSTRUCTION MANUAL 

 

 

Leak

finder

®

 

Model No. 625-WV609 

BMW Smoke Tester

 

 

 

Diagnostic Smoke

®

 

Vapor

 

with UltraTraceUV®

 

Dye Solution

 

 

Leak Detection System for the Professional Technician 

 

 

 

 

USA | Canada Patents 

 6,392,227 • 6,439,031 • 6,526,808 | 2,279,147 • 2,394,911 | Int’l Patents Pending 

 

 

Summary of Contents for Leakfinder 625-WV609

Page 1: ...del No 625 WV609 BMW Smoke Tester Diagnostic Smoke Vapor with UltraTraceUV Dye Solution Leak Detection System for the Professional Technician USA Canada Patents 6 392 227 6 439 031 6 526 808 2 279 147...

Page 2: ......

Page 3: ...ne turned OFF Use this equipment in the manner specified by the manufacturer Follow common sense safety precautions Connect to grounded extension cord supplied and grounded 120 volt AC 60 Hz wall outl...

Page 4: ...vehicle system leaks Smoke vapor generating leak detectors containing STAR Technology inside are the only leak detectors in the world approved by BMW The patented technology inside your Leakfinder inc...

Page 5: ...locates leaks around doors windows sunroofs and trunk compartment seals Adapter Cone standard 625 WVA 01 for introducing smoke into the exhaust system or the induction system Cone is 1 x 3 5 and 6 lo...

Page 6: ...r Separator Filter inside tester with drain port at underside of tester keeps tester and vehicle clean by automatically draining water and contaminants from workshop air compressor It is normal to occ...

Page 7: ...n Manual in its entirety before operating this tester Low Full Pour entire contents of one 12 oz UltraTraceUV solution bottle into the smoke chamber NOTE Use second bottle supplied to regularly mainta...

Page 8: ...VAP leak testing Connect to Nitrogen or other inert gas when testing fuel evaporative EVAP system Regulate nitrogen from 50 to 175 PSI 3 4 bar 12 bar 345 kPa 1 206 kPa Inert Gas Pack Inert Gas Pack Ki...

Page 9: ...ter to smoke tester and grounded extension cord supplied to grounded 120 Volt AC 50 60 Hz wall outlet and turn power converter ON Push in toward tester to lock pull out to unlock To remove plug First...

Page 10: ...ess START button Green and red lights are ON 5 minute timer Position to SMOKE full flow Use cone to access intake system and connect smoke supply hose to cone Refer to SI B 16 01 07 for additional inf...

Page 11: ...7 5 Use white light to find the smoke Use UV light and yellow glasses to find the dye...

Page 12: ...Exhaust Fluorescent Dye Deposit The UltraTraceUV smoke solution contains a special ultraviolet activated fluorescent dye that deposits at the exact location of a leak Use the UV light provided to hig...

Page 13: ...ea at te es s p po os si it ti iv ve e c ca ab bi in n p pr re es ss su ur re e 2 2 C Co on nn ne ec ct t s su up pp pl ly y h ho os se e n no oz zz zl le e t to o S Sm mo ok ke e D Di if ff fu us se...

Page 14: ...etermining if a leak exists and how large it is SMOKE Delivers maximum smoke volume FLOW CONTROL Controls smoke volume Locating the leak source is sometimes easier with less smoke volume First fill sy...

Page 15: ...es the leak size in the system being leak tested When using workshop air or nitrogen read the left side of the flow meter When using CO2 read the right side of the flow meter The 010 0 25 mm 020 0 5 m...

Page 16: ...until flow meter ball stops descending Be sure the Leakfinder is still ON and immediately position control valve to TEST for a more accurate flow meter reading Be sure ball has stopped descending and...

Page 17: ...ne and wall outlet There is no air or smoke coming out of the supply hose 1 Flow Control valve is closed 2 Air gas supply to tester is insufficient 3 Bad power supply cable connection or power convert...

Page 18: ...r or at Seller s option replacement of or refund of the original purchase price for Equipment or parts which to Seller s satisfaction are determined to be defective and which are necessary in Seller s...

Page 19: ...15...