description of parameters
vacon
•
17
24-hour s358 (0)40 837 1150 • Email: [email protected]
Speed Curve 1 parameters (M2 -> G2.2.5)
Parameters in group Speed curve 2 are used when internal ramp switch function is
activated (see parameter P2.2.5.1). Then the Speed curve 1 parameters will be
replaced by Speed curve 2 parameters.
2.2.5.1 Internal Ramp switching frequency
0 = Not used
The ramp set 2 (Speed Curve2 parameters) can be activated internally. The update is
done when the speed is decelerated below the internal ramp switch frequency and the
reference frequency is reached.
Ramp set 1 (Speed Curve1 parameters) is changed back when the Run request of the
frequency converter is inactivated.
2.2.5.2
Acceleration time 2
2.2.5.3
Deceleration time 2
Acceleration and deceleration of the lift car are presented in [m/s2]. Acceleration and
deceleration curves are affected by the jerk time settings, too.
2.2.5.4
Acc inc jerk 2
Acceleration increase jerk 2. See Figure 1. Jerks related to speed and acceleration.
2.2.5.5
Acc dec jerk 2
Acceleration decrease jerk 2.
2.2.5.6
Dec inc jerk 2
Deceleration increase jerk 2.
2.2.5.7
Dec dec jerk 2
Deceleration decrease jerk 2.