background image

4 Care and maintenance

Long-life activated charcoal filter

When the extractor fan is switched off and the glass canopy is pulled out, all the level in-
dicators flash for 40 seconds after 160 operating hours. The saturation level has been
reached. The long-life activated charcoal filter has to be cleaned and reactivated.

Only activate this function if the appliance is being used in the recirculation mode.

Care and maintenance

4.1 

Cleaning the housing

Take care that no water gets into the housing of the appliance! If water gets into
the housing, it can cause damage.

Do not use abrasive cleaners, scouring pads, steel wool, etc. for cleaning, as they
can damage the surface. Disconnect the appliance from the mains and unscrew
the fuse or switch off the automatic circuit breaker.

Cleaning the outside/inside

▸ Clean the outside of the appliance with a warm, damp cloth and a little detergent and

then wipe dry.

Grease and condensate water can build up on the inside around the metal grease
filters.

▸ Clean with a warm, damp cloth and a little detergent – you can also use a brush if ne-

cessary – and then wipe dry with a kitchen towel.

4.2 

Metal grease filters

The metal grease filters must be cleaned at least once a month with normal use. If prop-
erly cared for, the grease filters should provide years of service.

Removing

Do not damage the metal grease filters.

▸ Pull the glass canopy 

1

 completely out.

▸ Pull flap 

2

 down.

The grease filter 

3

 is unlocked.

▸ Tilt the front of the grease filter 

3

 down-

wards and pull forwards.

3

2

1

11

Summary of Contents for DFSG 5

Page 1: ...Operating instructions DFSG 5 6 8 9 Range hood...

Page 2: ...autions Modifications Text diagrams and data correspond to the technical standard of the appliance at the time these operating instructions went to press The right to make technical modifications for...

Page 3: ...3 2 Switching the appliance on 9 3 3 Extractor fan 9 3 4 Intensive level 10 3 5 After running time 10 3 6 Illumination 10 3 7 Switching the appliance off 10 3 8 Saturation indicator 10 4 Care and main...

Page 4: ...not play with the appliance Cleaning and user mainten ance shall not be undertaken by children without supervi sion If an appliance is not equipped with a mains cable and a plug or other means for di...

Page 5: ...culation appliances If other firing systems are being used at the same time e g wood gas oil or coal fired heating appliances safe op eration is only possible providing a room negative pressure of 4 P...

Page 6: ...1 Safety precautions 6 How to avoid damaging the appliance Observe the cleaning intervals Failure to do so can increase the fire hazard due to the build up of grease in the metal grease filters...

Page 7: ...rough the metal grease filters the cooking fumes and smells above the cooking area are passed through an activated charcoal filter The filtered air is then circulated back into the room through the si...

Page 8: ...ensive level Level 3 after running time level 3 Level 2 after running time level 2 Switch extractor fan on off level 1 reset saturation indicator Switch illumination on off can be operated from above...

Page 9: ...activated charcoal filter Switch the appliance off Hold the and buttons depressed for 3 seconds power level 2 and intensive illuminate in the display The appliance is now configured as an extraction...

Page 10: ...unning time 1 20 minutes 2 15 minutes 3 10 minutes Intensive 5 minutes 3 6 Illumination Press the button to switch the illumination on Press the button repeatedly to switch the illumination off The il...

Page 11: ...e the surface Disconnect the appliance from the mains and unscrew the fuse or switch off the automatic circuit breaker Cleaning the outside inside Clean the outside of the appliance with a warm damp c...

Page 12: ...are positioned properly in the receiving slots 2 Resetting the saturation indicator With the appliance switched on hold the button depressed for 2 seconds to reset the saturation indicator All the di...

Page 13: ...d charcoal filter mat 3 with hot water and detergent and then soak in hot water in the sink for an hour Rinse well afterwards To reactivate the activated charcoal the activated charcoal filter mat 3 w...

Page 14: ...r wards out of the bracket Remove the activated charcoal filter unit 1 from the appliance housing 2 and regenerate in the oven Allow to cool Reassemble in the reverse order 1 2 Cleaning and reactivati...

Page 15: ...ppliance is not extracting enough air Possible cause Solution The metal grease filters are dirty Clean the metal grease filters Only for recirculation mode The activated charcoal filters are saturated...

Page 16: ...y Class EEC A Fluid Dynamic Efficiency FDEhood 30 4 Fluid Dynamic Efficiency Class FDEC A Lighting Efficiency LEhood lux W 17 0 21 0 Lighting Efficiency Class LEC C B Grease Filtering Efficiency GFEho...

Page 17: ...a safe location or dispose of it in an environmentally friendly way 8 2 Safety Render the appliance unusable to prevent accidents caused by improper use e g through children playing Disconnect the app...

Page 18: ...10 Initial set up 4 Intensive level 10 M Model designation 2 O Operating elements 8 20 Operating the appliance 9 P Product fiche 17 Q Queries 19 R Recirculation mode 7 S Safety precautions Before usi...

Page 19: ...hem on the identification plate of your appliance My appliance information SN __________________________ Appliance ______________________________ Please have this appliance information to hand when co...

Page 20: ...er running time level 2 Switch extractor fan on off level 1 reset saturation indicator Switch illumination on off can be operated from above or below V ZUG Ltd Industriestrasse 66 CH 6302 Zug Tel 41 5...

Reviews: