6 Operating the range hood
6.4
Room ventilation
With the room ventilation function, the air is cleaned irrespective of whether cooking
zones are in operation. The range hood is switched on and off manually.
The cooking zones cannot be operated when room ventilation is running.
▸ Remove all cookware from the cooking zones beforehand.
▸ Touch the button.
–
The appliance switches on.
▸ Touch
.
–
is underlined.
▸ Touch .
–
The slider appears.
▸ Set the required power level.
–
Room ventilation is activated.
▸ Touch
to switch the function off again.
–
The range hood continues to run according to the after-
running time.
6.5
OptiLink
With this function, the user no longer needs to control the range hood manually. OptiLink
monitors the power levels set for the cooking zones and automatically sets the optimum
power level for the range hood.
The following settings are available for selection:
OFF
OptiLink is switched off
Silent mode
Low noise level operation
Standard mode
Normal mode
Intensive mode
High power for extracting cooking fumes and smells
▸ Use a wooden spoon together with the pan lid to vent
the steam into the suction inlet of the range hood.
24