13 Spare parts
13
Spare parts
Please state the serial number (SN) when ordering parts.
Further spare parts can be purchased from the spare parts shop at
.
Door filter with
door filter mat
Door filter mat
Front insert
Front filter
14
Technical data
General notes
Height
85 cm
Width
59.5 cm
Depth
61 cm
Weight
65 kg
Pumping height of pump
1.2 m
Load capacity
7 kg dry washing
Permissible room temperature for
the tumble drying operating mode
5 °C to 35 °C
Permissible room temperature for
the room air drying operating
mode
8 °C to 35 °C
Electrical connection
The electrical connection can be found on the identi-
fication plate (see page 51).
14.1
Note for testing institutes
Tumble drying operating mode
▸ The appliance must be connected to the electricity supply for at least 5 minutes be-
fore taking measurements.
▸ Close the air inlet and outlet flaps to set the
tumble drying operating mode.
▸ The declaration data can be determined correctly only after a run-in phase of 5 com-
plete drying programmes with washing (automatic programme: normal dry
).
▸ Wash the door filter each time after completing a drying programme.
▸ The moisture sensor of the appliance is calibrated based on average water hardness
levels. To adjust the water conductivity value of the appliance according to the norm
(750 µS/cm), the level of dryness for tumble drying must be set to «1» in the user set-
tings (see page 29).