5 Trouble-shooting
4.4
Reset saturation indicator alarm
Reset the saturation indicator alarm for both the metal grease filter (LED for button
flashes) and the activated charcoal filter (LED for button flashes) after cleaning/repla-
cing.
▸ Hold the button depressed for 5 seconds.
–
If reset successfully, the LED for the or button will stop flashing.
4.5
Replacing the LED light bulbs
For safety reasons, the LED light bulbs must be replaced by our Customer Services.
5
Trouble-shooting
This section lists faults that can be solved simply by following the instructions given. If
the fault cannot be remedied, please call Customer Services.
Before calling Customer Services: Please note down the serial number (for SN, see iden-
tification plate under «Technical data») and what led to the fault.
Malfunction
Possible cause
Solution
Appliance is not working.
▪
Interruption in the power
supply.
▸ Check the power supply.
▸ Change the fuse.
▸ Reset the automatic circuit
breaker.
Illumination is not work-
ing.
▪
LED light bulb is defective. ▸ Contact Customer Services.
Malfunction
Possible cause
Solution
Appliance is not extract-
ing enough air.
▪
Metal grease filters are
dirty.
▸ Clean metal grease filters.
▪
Recirculation mode only:
Activated charcoal filters
are saturated.
▸ Clean and reactivate or re-
place activated charcoal fil-
ters.
▪
Extraction mode only: In-
sufficient fresh air intake.
▸ Ensure fresh air intake is suf-
ficient.