14 Technical data
14
Technical data
Abmessungen
EURO 60
Grossraum
Gerätehöhe
(bis Blende)
821 mm
Gerätehöhe
(inkl. Verstellsockel)
845–893 mm
Gerätebreite
596 mm
Gerätetiefe
572 mm
Gerätegewicht
49–56 kg
Plumbing in
Cold or hot water up to 60 °C:
G¾"
Permitted pressure of water supply:
0.1–1.0 MPa (1–10 bar)
Max. pumping height:
1.2 m
Electrical connection
The electrical connection data can be
found on the identification plate:
▸ Open the appliance door.
–
The identification plate is located on
the left-hand side on the edge of the
tub.
Ambient conditions
Minimum ambient temperature
+10 °C
Warranty claim
The manufacturer’s warranty is valid for 24 months starting from when the appliance is
first put into service.
14.1
Safety concept
Provided power is going to the appliance, the electronic control unit monitors the appli-
ance. Any malfunctions are indicated by error messages.
14.2
Overflow protection
The overflow protection system does not function during a power failure. Turn off
the water tap during longer periods of inactivity.
The electronic control unit monitors the water level in the appliance. In the event of
a malfunction, the drain pump turns on, stopping the supply of water to the appli-
ance.