background image

Installation instructions

Microwave
Type of construction 60-381

J945.113-2

1.3.12  WIMA

1

 

These installation instructions apply to the models: 

945

947

 

Identification plate

A

Open appliance door. The identification plate is located at the front on the bottom left-hand 
side (see illustration).

A

Information on the necessary mains voltage, type of current and fuse protection can be taken from the identification plate.

 

The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order
specified.

Validity

General notes

If fitting in flammable material, the guidelines and standards for low voltage installations and for the fire protection must be
strictly observed.

Electrical connections

Electrical connections must be carried out by trained electricians in accordance with the guidelines and standards for low
voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should
always be checked.