12
Figure 8. V-Power S14 grounding
2.4
Connecting Power Cable
Context
1. Insulate installation tools to prevent electric shocks.
2. According to the power value of the inverter, the power cable should be connected. If multiple batteries are used in
parallel, the power cables should be connected according to the wiring mode in Figure 11~13.
3. More than 2 batteries are used in parallel, a "Junction Box" is required, first connect the power cable of each battery
to the junction box, then connect the power cable from the junction box to the inverter.
The V-Power S14 power cable connection method adopts a self-locking connector. The description of
the self-locking connector is shown as follows:
The steps for connecting the self-locking connector are as follows:
A
Adjust the direction of the self-locking connector to align with the V-Power S14 terminal.
B
Rotate the self-locking connector slightly, and it will be inserted automatically.
C
After the self-locking connector is automatically inserted, push it in slightly, and after hearing a
click sound, the self-locking connector and the battery module terminal are connected.
Need to press the buttons on the self-locking connector simultaneously when users need to pull
out the self-locking connector.