background image

V

1

.

0

 

V-T48160

VTAC Volts 

 

Instruction Manual

Summary of Contents for V-T48160

Page 1: ...V1 0 V T48160 VTAC Volts Instruction Manual...

Page 2: ......

Page 3: ......

Page 4: ...12 2 3 System diagram 7 3 1 Unpacking inspection 8 4 Electrical connection 11 3 4 Drilling safety 10 4 2 3 RS232 communication point definition 12 5 2 2 Screen 16 4 3 System connection diagram 13 2 1...

Page 5: ...not operate under the service conditions described in this manual The installation and use environment exceeds the provisions of relevant international or national standards Disassemble change the pro...

Page 6: ...efore using the tool please master the correct use method of the tool to avoid personal injury and equipment damage When the equipment is running the shell temperature is high and there is a risk of b...

Page 7: ...medical help immediately Fire treatment measures In case of fire the system should be powered off under the condition of ensuring safety Use carbon dioxide FM 200 or ABC dry powder fire extinguisher...

Page 8: ...perience can be aware of the risks that may be brought to him during a certain operation and can take measures to minimize the risks to himself or other personnel Operators operators who may come into...

Page 9: ...appropriate specifications 2 Product introduction 2 1 Product introduction Function Li ion battery includes only battery modules which can store and release electric energy according to the requiremen...

Page 10: ...losed when a low battery alarm signal has occurred RS232 RS232 communication interface for battery condition monitoring RS485 communication interface Used in communication parallel and for battery con...

Page 11: ...nicate with the battery energy storage system The Inverter can be connected through CAN interface to realize the communication and control between the inverter and battery The battery can be accessed...

Page 12: ...ansion screws M10 MSDS Transportation certificate RS232 communication line Power line 1m Parallel line Customized according to customers RS485 communication line Customized according to customers 3 2...

Page 13: ...block the vent or cooling system Maintain the battery operating temperature for charging 0 55 C and discharging 20 60 C Do not store or install the battery in an environment of flammable or explosive...

Page 14: ...top to bottom Ensure that the center of gravity of the body does not deviate from the edge of the ladder 3 4 Drilling safety The following safety precautions shall be considered when drilling on the w...

Page 15: ...the battery lock the M6 40 screw at the top of the support fix the battery and place the battery to slide installation is complete 4 1 Cable connection 4 Electrical connection Anderson connector is u...

Page 16: ...nication connects the battery with the inverter to function as duo for operations RS485 communication The additional two RS485 interfaces can be used for parallel connections with other batteries or t...

Page 17: ...lor Description DC positive wire DC negative wire Ground wire Live Wire Naught wire Communication line 4 4 battery connection 4 4 1 Single battery connection PV PV N GND L BAT RS485 OR CAN AC_OUT AC_I...

Page 18: ...ess of ads needs to be assigned as shown below Address 2 3 4 5 6 7 8 9 10 11 12 13 1 0 14 15 Dial switch Remark 1 2 3 4 OFF OFF OFF OFF ON OFF OFF OFF OFF ON OFF OFF ON ON OFF OFF OFF OFF ON OFF ON OF...

Page 19: ...nterfaces The installation environment meets the requirements The installation is correct firm and reliable The cable layout is reasonable to meet the user s requirements The cable ties shall be unifo...

Page 20: ...2 3 4 5 6 7 Addr Rem Cap Tol Cap Temp1 4 Environment temperature MOS Temperature Battery Cell Voltage Battery Pack Address Remnant capacity Total capacity Battery Temperature Env Temp MOS Temp Cells1...

Page 21: ...arge high temperature protection PCB Protection Sample Protection NTC chg MOS dhg MOS 18 Cells Battery Cells Protection Battery Information Alarm Status NO NO Items Description Items Description 1 2 3...

Page 22: ...voltage and the duration reaches the sleep delay time no communication no protection no balance and no current The standby time exceeds 24 hours no communication no charge and discharge no mains power...

Page 23: ...age Charge Normal Alarm Over Charge protection Temperature Over current Fault Protection The maximum power LED flashes flashes 2 and the overcharge alarm ALM does not flash ON ON ON OFF Flash 3 OFF OF...

Page 24: ...le into the battery wireless kit port download the wireless kit app and register the account after installation After turning on Bluetooth WiFi GSM click Add device The maximum connection range of Blu...

Page 25: ...d Device or to add products The Message is after sales service Click the connected battery to view the following information Battery information You can view the relevant information of battery voltag...

Page 26: ...e protection DOTP 15 16 17 19 20 21 COTP PCB Sample NTC Protection Charge MOS protection Discharge MOS protection Charge high temperature protection PCB Protection Sample Protection NTC chg MOS dhg MO...

Page 27: ...environment Double click the main program icon to run it 6 2 Connect the upper computer Ensure that the BMS board is normally powered on and not in sleep state the crystal head of the communication li...

Page 28: ...ADDR Intervals Close Serial port you can select the drop down item to select the serial port to communicate Note available when the serial port is not opened Baud rate you can select the drop down it...

Page 29: ...itch control Click to enter the screenshot status and the toolbar will appear after marking out the screenshot area with the mouse Displays the flag icon of the current language country Click to switc...

Page 30: ...he data has not been saved Clear interface data Click the button CLS to clear the real time data on the interface Record data Check Data save to database to start recording data When there is data rec...

Page 31: ...ace to local Delete record delete the storage record of BMS board when reading the prompt no more data indicates that the reading has been completed 6 3 4 Parameter setting Interface Click the main in...

Page 32: ...ritten into the BMS If you need to write please execute the write operation 6 3 5 System settings Interface Click the main interface tab System Config to enter the interface function Just follow the i...

Page 33: ...ependently but only needs to meet the environment Double click the main program icon to run it Connect the computer to the battery via the USB RS485 communication cable Setting for DID Click to open t...

Page 34: ...no tools or other parts are missing in the equipment 8 Battery storage requirements When the battery is stored it shall be placed correctly according to the identification of the packing box and shall...

Page 35: ...The replaced products shall be handled by the company and the customer shall leave a certain time for the company to deal with the faults 10 Exemption from liability The company has the right not to c...

Page 36: ......

Page 37: ......

Reviews: