V-Sun TLT-3 User Manual Download Page 1

 

 

 

 

 

 

 

TLT-3 

 User Manual 

(TLT-3 GPS/GSM Vehicle Tracker) 

 

 

V1.0 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manual update records 

Summary of Contents for TLT-3

Page 1: ...TLT 3 User Manual TLT 3 GPS GSM Vehicle Tracker V1 0 Manual update records ...

Page 2: ...TLT 3 GPS GSM Vehicle Tracker User Manual V1 0 2 Version Updates Author Date V1 0 Manual initial order 2010 8 16 Product main features ...

Page 3: ...asy to install 2 Features 1 built in JRC SKYTRAQ high performance GPS chipset In weak signal conditions can pinpoint in urban canyons and other areas with limited sky view can be good work 2 built in GSM GPRS module support GSM900 1800MHz 850 1900 optional to do can work worldwide 3 support for SMS communication or GPRS TCP connection can be to receive location information by SMS or the Internet t...

Page 4: ...GSM module MTK program GSM 900 1800 850 1900 dual band or quad band optional support for TCP protocol GPS chip JRC SKYTRAQ high sensitivity GPS chipset GPS Sensitivity 164dBm GPS frequency L1 1575 42MHz C A code 1 023MHz Passage 210 channel full track Location accuracy 2 5m CEP Speed Accuracy 0 1 m s Time accuracy 1 us and the GPS time synchronization ...

Page 5: ...midity 5 95 No coagulation Size 88mm 50mm 20mm Voltage 12V 3 2 LED status lights description 1 Blue LED instructions GSM signal state Status Meaning Flash No SIM card or no GSM network Flash once every 8s GSM receivers work well and stand 2 Red LED charging instructions like 3 Green LED direct GPS signal status 4 Annex 1 TLT 3 GPS GSM vehicle tracking device 2 the power line Status Meaning Always ...

Page 6: ... step a product owner stored telephone numbers non stored the same number of products to respond to instructions sent and then modify the device configuration information Products of the factory configured in the appendix Command as follows Instruction Format new number 4 20 bit Password 4 number 1 3 Such as 13900000000 0000 1 Description User initial password is 0000 TLT 3 can be stored up to thr...

Page 7: ... After the success of the sender to send the confirmation to the SET MODE OK CURRENT MODE SMS P2P GPRS online mode Command format 710 User Password 4 Such as 7100000 Description When the TLT 3 received the SMS to confirm the user password is correct the switch to GPRS mode After the success of the sender to send the confirmation to the SET MODE OK CURRENT MODE GPRS Applications based on SMS mode o...

Page 8: ...Status A V ID IMEI STATE Information Status Valid data sample Lat 22 50500 Long 114 01000 Speed 0 00KM H Direction 315 00 Date 2008 04 25 Time 16 39 45 BS 25ee0dff Fix A ID 353686009002030 STATE SMS Invalid data sample Lat 22 50500 Long 114 01000 Speed 0 00KM H Direction 315 00 Date 2008 04 25 Time 16 39 45 BS 25ee0dff Fix V ID 353686009002030 STATE SMS Note If the cold start and the GPS does not ...

Page 9: ...ude longitude position of the corresponding detailed 1 download Google map software from http earth google com 2 open the Google Maps software for more information on the Google Maps software please refer to http earth google com as shown below Note change in location data format Send 666 code SMS command to the TLT 3 by latitude and longitude data Enter your ...

Page 10: ...transmitted from tracker as follows Lat 22 50500 Long 114 01000 Speed 0 00KM H Direction 315 00 Date 2008 04 25 Time 16 39 45 BS 25ee0dff Fix A ID 353686009002030 STATE SMS Find locations in Google Maps enter in the appropriate location 22 50500 114 01000 Obtain the following picture Or you can use the PDA or navigation device on a local map software enter the location data Note change in location...

Page 11: ... the user password for the new user password set up after the success of confirmation to the sender to send a short message Content for the SET USER PASSWORD OK 2 GPS status is set to command Send SMS commands can work on the GPS on off two states GPS factory set or reset for the normal open state 1 open the GPS instruction instruction format 222 user password 4 For example 2 220 000 Description W...

Page 12: ... arrival interval time to send the previous one time positioning request return message format location information which information items automatically update the state STATE TIMER When XX is 00 the cancellation of regular orders to send position information the sender s mobile phone to send a confirmation message TIMER STOP Note The current version of the maximum time interval of not more than ...

Page 13: ...tate prompted the STATE OS Also call a telephone number stored in the first If unsuccessful shutdown or not connected then in turn call the second third When TLT 3 re entering the fenced area will be set immediately sent to the No 3 time in front of pre existing single positioning request message format returned location information Information in the state prompted the STATE RS Also call a teleph...

Page 14: ...word immediately after reading the latest GPS data and determine the validity of the second is for the A effective the extraction of the current coordinates of latitude and longitude information as a fencing center of a circle and to R value of the radius while open electronic fence a successful return after the first sending confirmation SET GEO FENCE OK GPS data is invalid if the date is to give...

Page 15: ...X example 122 0000 250 Note X is the speed reference value the data type integer in units of km hour KM H the domain of 0 999 When TLT 3 received the order to confirm the user password is correct it will set the speed reference value X X 0 时 close the speed alarm function X 0 speed alarm function is turned on after the success of the first stored to the user send confirmation message SET RATE LIMI...

Page 16: ...0 then close the historical data record if X 0 then began to X seconds as the time interval the received GPS data is stored after the successful transfer back to the sender to confirm Xin Xi SET SAMPLING OK Note 1 record the size of each data about 100B BYTE 2 historical data records for storage space allocated to 864KB BYTE data storage stack covered with an updated approach Suppose X 30 you can ...

Page 17: ...on When the TLT 3 received the order to confirm the user password is correct the automatic restart and automatically log on FTP server to download program When the update again after a successful reboot into normal use Note FTP address is stored within the machine 2 instruction format User password FTP address user name password for example 0000 Igarin gicp net tracker trac Description When the TL...

Page 18: ...please according to the local service provider s APN to choose to use the instruction format 1 or format 2 instruction set Explain 2 When the TLT 3 receiving the order confirm the user password is correct update GPRS access point for the new access point set up after the success of confirmation to the sender to send a short message If you send the order form 1 then back to confirm the information ...

Page 19: ...n to connect GPRS server and the data sent If due to network or other causes of data not sent to the server the data is automatically backed up when the network returned to normal after the replacement data to the server From advanced applications of data formats such as GPRS 7 Immediately upload the contents of the current position back the data in the state labeled AUTO When set to upload data e...

Page 20: ...ctory set or reset for the normal open state 1 open the GPS instruction instruction format 222 user password 4 For example 2 220 000 Description When the TLT 3 receiving the order confirm the user password is correct open the GPS power after the success of the sender to send the confirmation to the GPS ON OK 2 close the GPS commands command format 333 user password 4 For example 3 330 000 Descript...

Page 21: ...ongitude value precision after the decimal point 5 Speed speed KM H precision after the decimal point 2 Direction Heading accurate to two decimal places Date Date YYYY MM DD Time Time HH MM SS GMT BS base station information FIX Position Status A V ID IMEI STATE Information Status Valid data sample Lat 22 50500 Long 114 01000 Speed 0 00KM H Direction 315 00 Date 2008 04 25 Time 16 39 45 BS 25ee0df...

Page 22: ...ername Note When TLT 3 receiving the order confirm the user password is correct update the user called the new user name set to the sender after the success of short message sent to confirm CHANGE USERNAME OK 6 GPRS service password change Instruction Format 802 service password user password new password old services such as 802 0000 1111 0000 Description When TLT 3 receiving the order confirm th...

Page 23: ...0 315 00 251207 A 6E 25ee0dff GPRMC 083955 180 A 2233 4249 N 11406 0046 E 0 00 315 00 251207 A 6E Note The data format immediately upload status SMS 8 Calling switch instruction Calling off instruction format 150 user password for example 1500000 calling open instruction format 151 user password for example 1 510 000 Description When the TLT 3 before calling the relevant instructions to confirm th...

Page 24: ... connected then in turn call the second third When TLT 3 re entering the fenced area will be set immediately sent to the server 3 2 10 format location information Tips for the state information RS Also call a telephone number stored in the first If unsuccessful shutdown or not connected then in turn call the second third 1 Set the fenced area According to the different coordinates input format the...

Page 25: ...ngitude information which ddd ddddd that degree Decimal point behind the five followed by zero can not be omitted Ndd ddddd is a degree of latitude in units of information which dd ddddd that degree Decimal point behind the five followed by zero can not be omitted zzz z is the domain of radius 999 9 0 1 units KM When TLT 3 received the order to confirm the user password is correct return to the se...

Page 26: ...rt message GEO FENCE ON 12 Close electronic fence 210 user password when the TLT 3 received the order to confirm the correct password after the close of electronic fence to return to the sender to confirm the short message GEO FENCE OFF 13 Overspeed alarm function instruction format 122 user password X example 122 0000 250 Note X is the speed reference value the data type integer in units of km ho...

Page 27: ...e sampling frequency an integer the domain of 0 999 unit is seconds When TLT 3 received the order to confirm the user password is correct set the historical record of the sampling frequency is X If X 0 then close the historical data record if X 0 then began to X seconds as the time interval the received GPS data is stored after the successful transfer back to the sender to confirm Xin Xi SET SAMPL...

Page 28: ...ation information shown Information in the state prompted the STORAGE 15 invalid data is uploaded switch command format 08X user password 4 Function When the TLT 3 receiving the order confirm the user password is correct according to the value of X is upload invalid data set switch state X 1 open the invalid data uploading After the success of the sender set to send a confirmation SMS INVALID DATA...

Page 29: ... reboot and automatically login FTP address server download When the update again after a successful reboot into normal use Note FTP address length 5 35 can also domain names letters numbers dot Underscore _ and hyphen form User name FTP server user name length 3 20 password for the FTP server password length 3 20 User name and password respectively numbers and letters Accessibility operation 1 Di...

Page 30: ... power switch off oil RATE XX speeding baseline ST time location information requested time interval TN SMS mode timer request number INVALID UPLOAD invalid data upload switch MOVE displacement alarm radius displacement alarm switch ACC PROMPT ACC switching state switch GU GPRS user name password SRV Server IP address port number APN GPRS access point APN username APN Password SAMP From the sampli...

Page 31: ...n CALL A fence OS Finalists selected RS Speed alarm OVERSPEED Safe speed SAFESPEED Historical Data Upload STORAGE 806 single hair positioning SMS From time to time to go car track AUTO Reset Status List configuration state configuration state configuration state Working mode Point to point Stored calls Empty GPRS user name V500 GPS Statu On Timing send Stop Speed alarm Close ANP CMNET IP Address 0...

Page 32: ...Set alarm of over speed 100 user password Open power saving function in two modes 150 user password Close calling instruction in two modes 151 user password Open calling instruction in two modes 211 user password Open the electronic fence in two modes 210 user password Close the electronic fence in two modes 222 user password Open GPS In two modes 333 user password Close GPS In two modes 4xx user ...

Page 33: ...in GPRS mode 807 password x Set historical sampling rate 808 password 24 Uploading the 24 hours historical data 808 password Uploading all the historical data 809 password x y Uploading data in Parking throttling mode RESET user password Reset all the configuration information after reboot RESTART user password Restart device GTAN Read all the current numbers passwords GTAS Read current settings U...

Reviews: