Before use, please take the time to read this datasheet and make sure 

you understood the advices and caution of use. 

 

 

 

 

 

Do not disassemble or modify the control unit. Doing so may result in fire or electric shock.  

 

Make sure that the control unit is free of moisture or any liquid. Exposure to water or other liquid may result in fire or 
electric shock.  

 

Do not touch the plugs or switches with wet hands. Doing so may result in electric shock.  

 

Before connecting or disconnecting cables, make sure that the power switch is turned OFF. Failure to do so may results 
in fire, electric shock, or breakdown in the UV LED lamp. Before moving the control unit, disconnect all cables.  

 

If an abnormal condition, such as smoking, abnormal heating, abnormal odor, or noise, occurs, stop using the control 
unit immediately and turn OFF the power switch. Continued use may result in fire or electric shock.  

 

Do not place the control unit in direct sunlight or in a very humid environment. Doing so may result in fire due to 
internal temperature rise. Observe the limitations of the operating temperature and humidity.  

 

Do not install the control unit perpendicularly. Always place the control unit on a stable and flat surface. Not doing so 
may result in the control unit falling or toppling, which may cause bodily injury or control unit malfunction.  

 

Do not pile up the control units. Doing so may result in fire due to internal temperature rise.  

 

Use a cable manufactured by UWAVE to connect the UV LED lamp. Use irradiators that are suitable for the control unit 
ratings. Doing so may cause control unit failure.  

 

Please secure a wiring space to the back panel and respect bending radius of cables. Damaging the cables may result in 
fire or electric shock.  

 

Any incorrect use cancels the warranty. 

 

Security of the user 

Summary of Contents for UPOWER-1500-48

Page 1: ...such as smoking abnormal heating abnormal odor or noise occurs stop using the control unit immediately and turn OFF the power switch Continued use may result in fire or electric shock Do not place the control unit in direct sunlight or in a very humid environment Doing so may result in fire due to internal temperature rise Observe the limitations of the operating temperature and humidity Do not in...

Page 2: ... 1 Rue de Terre Neuve 91940 LES ULIS FRANCE Tel 33 9 72 52 70 03 Fax 33 9 72 11 21 69 Email contact uwave fr Page 2 9 Table of contents 1 3 4 5 7 8 9 Security of the user Technical overview Names and functions of parts Quick start ON OFF MODE TIMER MODE Mechanical dimensions mm ...

Page 3: ... delivered 1500 W Input power Single phase 85 to 264 VAC 50 60 Hz Connector to 220V IEC C14 Output voltage and current 48 VDC and 32 A for one Channel Connectors to UV products SUBD13W3 Inrush current typ 30 A at 115 VAC and 60 A at 230 VAC Ground leakage current 2 mA max at 240 VAC Mechanics W L H mm 250mm 410mm 120mm Weight 8 5 kg Material Device body Aluminum alloy Environment Working temperatu...

Page 4: ...y 20 Miniparc du Verger Bâtiment E 1 Rue de Terre Neuve 91940 LES ULIS FRANCE Tel 33 9 72 52 70 03 Fax 33 9 72 11 21 69 Email contact uwave fr Page 4 9 Front side UPOWER FAV 1500 TIMER Rear side UPOWER FAR 1500 TIMER Names and functions of parts ...

Page 5: ...th sides of the cable must be screwed 3 The M12 5 pins connector on the rear side named CHILLER is a security for water cooled UV LED lamps The control unit waits for a signal from the chiller in order to allow UV light emission If this step is not realized the UV LED lamp will not switch on Plug the water pipes from the chiller to the UV LED lamp and the M12 5 pins cable from the chiller to the c...

Page 6: ...o the electrical scheme below to install an external communication PLC Pin number Color Type Function 1 Brown out 24 VDC 2 White Out 0V GND 3 Blue In 0 VDC UV emission not allowed 24 VDC UV emission allowed 4 Black Not used 5 Blue Not used M12 connector scheme on the left and Schunt picture on the right 5 Connect the power cable into the IEC C14 connector and into the wall Then the power switch ca...

Page 7: ...tiometer Launch UV light emission by pushing the START button and press START again to stop it Press STOP to switch off the light in case of an emergency When this button is engaged you must disengage it to allow UV light emission 2 With a PLC Verify that the chiller security is not activated water circulation or use a schunt connector on the chiller M12 5 pins connector at the back panel Choose t...

Page 8: ...d the UV light emission stops Press STOP to switch off the light in case of an emergency When this button is engaged you must disengage it to allow UV light emission 2 With a PLC Verify that the chiller security is not activated water circulation or use a schunt connector on the chiller M12 5 pins connector at the back panel Choose the UV light intensity between 20 and 99 thanks to the potentiomet...