Installation and Maintenance Manual 

 

 
READ AND UNDERSTAND ALL 
INSTRUCTIONS BEFORE INSTALLING OR 
USING THIS PRODUCT 

 

 

PERFORMANCE 
CONSIDERATIONS 

 

  

 

The performance of the UVD1000S UV disinfection chamber has 
been third party validated using accepted bio-assay techniques. The 
UVD1000S is equipped with both visible and audio lamp failure 
alarms. For your safety, it is necessary that you determine that the 
audio alarm can be heard where you use the water treated by the unit. 
It is possible to operate the unit with the lamp disconnected which will 
allow you to validate the adequacy of the audio alarm function in your 
installation.  The UV power source used with the UVD1000S is 
capable of controlling a solenoid valve which can shut off the water 
flow and protect against using untreated water in case the UV power 
source looses power for any reason or the lamp fails prematurely. The 
use of the optional solenoid valve is highly recommended. In order to 
optimize disinfection performance, you must only use the unit with 
water that meets the minimum standard and replace the UV lamp at 
recommended intervals. Failure to follow these guidelines will result in 
reduced disinfection performance.  
   

 

UV RADIATION HAZARD 

NEVER OPERATE UV LAMP OUTSIDE OF THE UV 
DISINFECTION CHAMBER – EXPOSURE TO UV LIGHT 
CAN RESULT IN EXTREME BURNING OF SKIN AND EYES  

 
 

 

Safety instructions – Please read 
carefully 

 

 

Danger

: Do not plug the unit in if any of the external surfaces or 

electrical parts are wet. Condensation on the disinfection chamber is 
normal. 
 

Danger

: To avoid possible electric shock, special care should be 

taken since water may be present near electrical equipment.  Unless 
referred to in these instructions, do not attempt repairs yourself. 
Contact the manufacturer for service advice. 

 
Danger

: Do not operate this system if it has a damaged electrical cord 

or plug, is malfunctioning, or has been dropped or damaged in any 
way. 

 
Caution

: Do not use this unit for anything other than its intended 

potable water application. The use of attachments not recommended, 
approved or sold by the manufacturer/distributor may result in an 
unsafe condition. 

 
Caution

: Before any cleaning or maintenance, always unplug the unit. 

 
Caution

: Protect your unit from freezing. Drain all water from the unit 

if freezing temperatures exist.  

 
 

         

 
                WATER QUALITY 

 

 

Your UV disinfection system requires clean water for optimum 
performance.  You should only operate your unit if the source water 
meets the following standards. 

 
 
 
 
 
 
 

 

INSTALLATION CAUTIONS 

 

n

Connect your UV unit to a grounded (3 pronged) receptacle (120V, 

60HZ) (

a GFI is highly recommended

) and ensure that the lamp 

connector ground wire is connected to the ground stud on the top of 
the reactor vessel. Note: Power source for applications outside of 
North America must match requirements of the unit (eg. 240V, 50Hz). 
 

o

UV Dynamics disinfection devices are designed to be installed on 

the cold water line only. 
 

p

 Vertical orientation of the disinfection chamber with the lamp 

connector pointing upwards is the preferred mounting configuration– 
the water source should only be connected to the inlet port on the 
bottom of the unit.  

CAUTION: 

When installing the unit horizontally be 

sure to have the inlet and outlet connections pointing up to insure that 
air can be completely purged from the disinfection chamber. 

 

 

q

Install your UV Dynamics disinfection system indoors in a protected 

area where the temperature does not fall below 4

°

C. (40

°

F) and the 

humidity level is low (to prevent condensation on the chamber).  This 
unit functions ideally in a temperature range from 9

°

C - 29

°

C. (49 – 

85F) 
 

r

Use teflon tape on all pipe connections. 

DO NOT USE ANY 

OTHER SEALANT. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Turbidity 

  < 

NTU 

Suspended Solids  

< 10mg/L 

Colour 

   

None 

Total Iron 

 

< 0.3 mg/L 

Manganese 

 

< 0.05 mg/L 

Hardness 

 

< 7 gpg 

Dynamics 

UV 

UVD1000 

+ UV SENSOR 

 

 

7

9

UV Dynamics Inc.    