UTLDM1
Digital Multimeter
GENERAL MAINTENANCE
Warning
If the current test leads are worn, replace test leads with identical or
compatible leads: 1000V 10A.
Warning
To avoid personal injury or damage to the meter, DO NOT wet the inner
parts of the meter. Regularly clean the meter case with damp cloth and a small amount of
detergent. Do not use abrasives or chemical solvents.
REPLACE BATTERIES & FUSES
Warning
To avoid incorrect readings and possible electric shock or personal injury,
when “
” appears on the display, replace the battery immediately. Turn off the meter
and disconnect the test probe from the meter before opening the back cover to replace
batteries or fuses. Gain access to batteries and fuse by using a screwdriver to loosen the
battery cover screws on the back of the meter and removing the cover.
GENERAL SPECIFICATIONS
▶
Operating Category: 600V CAT III, pollution degree: 2.
▶
Operating Elevation (< 2000 m)
▶
Operating Conditions: 0~40°C, <80% RH (do not use meter when temperature <10°C).
▶
Storage Conditions: -10~60°C, <70% RH (remove the battery).
▶
Temperature Coefficient: 1 × Accuracy/°C (<18°C or >28°C).
▶
Maximum Voltage between measurement end and ground: 600V DC or 600V AC RMS.
▶
Fuse protection: mA Grade: fuse F400mA/600V and 10A Grade: fuse F10A/600V
▶
Sampling rate: about 3 times/second.
▶
Display: 3 1/2 digits 2,000 count LCD display.
▶
Power supply: 1 x 9V battery.
Instruction Manual
English
P R O F E S S I O N A L V A L U E
Copyright © 2014 UTL. All Rights Reserved
WARRANTY
The UTL Digital Multimeter (UTLDM1) is warranted to be free from defects in materials and
workmanship for a period of one year from the date of purchase. This warranty does not cover
fuses, disposable batteries, or damage from drops, neglect, misuse, alteration, contamination,
or abnormal conditions of operation or handling. Resellers are not authorized to extend any
other warranty on behalf of UTL. To obtain service during the warranty period, contact your
nearest UTL service center directly. For full warranty details visit us online www.utltest.net.
DC VOLTAGE
Range
Resolution Accuracy
2V
1mV
± (0.5% + 2 dgts)
20V
10mV
200V
100mV
600V
1V ± (0.8% + 5 dgts)
Overload protection:
600V RMS
AC VOLTAGE
Range
Resolution Accuracy
200V
100mV
± (1.0% + 10 dgts)
600V
1V
Overload protection:
600V RMS
DC CURRENT
Range
Resolution Accuracy
20mA
0.01mA
± (1.0% + 5 dgts)
200mA
0.1mA
10A
0.01A ± (2.0% + 8 dgts)
mA, μA Overload Protection:
250V RMS
10A Overload Protection:
600V RMS
TEMPERATURE
Range
Resolution Accuracy
-20°C to 1000°C
1°C ± (2.0% + 2 dgts)
-4°F to 1832°F
1°F ± (2.0% + 4 dgts)
RESISTANCE
Range
Resolution Accuracy
200Ω
0.1Ω
± (0.8% + 3 dgts)
2kΩ
1Ω
20kΩ
10Ω
200kΩ
100Ω
2MΩ
1kΩ
Overload protection:
250V RMS
DIODE
Range
Test Current Open Test Circuit
0.5 to 0.7V 1.2mA
2.7V
BATTERY TEST
Range
Resolution Test Current
1.5V
0.001V 40mA
9V
0.01V 10mA
12V
0.01V 10mA
CONTINUITY
Overload Protection Open Test Circuit
250V RMS
2.7V
17048 03/14
ELECTRICAL SPECIFICATIONS
1
yr.
warranty
IEC61010-1
99 Washington Street
Melrose, MA 02176
Phone
781-665-
1400
Toll Free 1-800-517-8431