4
Dimensions
PHYSICAL DATA
Central Heating (Sealed System)
125 / 150
165/ 205
Heat Exchanger Max Allowable Working
Pressure
50 psi [3.45 bar]
50 psi [3.45 bar]
Max System Pressure
43
.00
psi
[2.96 bar]
43
.00
psi
[2.96 bar]
Min System Pressure
7.25
psi [ 0.50 bar]
7.25
psi [0.50 bar]
Max System temperature
176°F
[80°C]
176°F
[80°C]
Pressure Relief Valve Setting
30
.00
psi [2.11 bar]
30
.00
psi [2.11 bar]
Expansion Tank Minimum Size
(pre-charge
press.)
2.2
gal at 11.6 psi
[10.0
L at
0.8 bar]
2.2
gal at 11.6 psi
[10.0
L at
0.8 bar]
Recommended System Pressure (cold)
21.7 psi [1.5 bar]
21.7 psi [1.5 bar]
Domestic Hot Water (Sealed System)
150
205
Max Inlet Water Pressure
116 psi [8 bar]
116 psi [8 bar]
Min Inlet Water Pressure
2.9 psi [ 0.2 bar]
2.9 psi [0.2 bar]
Min DHW Flow Rate
0.55 gpm [2.50 L/min]
0.55 gpm [2.50 L/min]
Max DHW Temperature
140°F [60°C]
140°F [60° C]
DHW Water Content
0.05 gal [0.23 L]
0.10 gal [0.37 L]
SYSTEM
When boiler is operating at maximum operating temperature, providing heating with all heat emitters operating, pressure gauge
should not indicate more than 26.11 psi / 1.80 bar. If reading exceeds this figure larger expansion tank is required.
240011941 REV B, [03/31/2018]
DIMENSIONS
125 & 150
205 & 165
Height
30" [763 mm]
30 " [763 mm]
Width
17
3/4
" [450 mm]
17
3/4
" [450 mm]
Depth
13
9/16
" [345 mm]
21
1/2"
[571 mm]
Condensate Trap Connection
13/16"
[21mm]
ID Hose
3/4" [19.1 mm]
NPT
System Supply
3/4” [19.1 mm]
1” [25.4mm]
DHW Outlet (125 Optional)
1/2” [15.9 mm]
3/4” [19.1 mm]
Gas Connection
3/4” [19.1 mm]
3/4” [19.1 mm]
DHW (Cold Water) Inlet
1/2” [15.9 mm]
3/4” [19.1 mm]
System Return
3/4” [19.1 mm]
1” [25.4mm]
Boiler Filling Connection
1/2" [15.9mm]
External to Boiler
Primary Water Content
1 gal [3.60 L]
1
1/4
gal [4.73 L]
B
A
C
D
E
F
G
H
I
J
Summary of Contents for MAC-150
Page 2: ...MAC 205 ...
Page 4: ...MAH 165 ...
Page 65: ...61 APPENDIX A WIRING DIAGRAMS A 1 MODELS 125 Heat Only 240011941 REV B 03 31 2018 ...
Page 66: ...62 APPENDIX A WIRING DIAGRAMS A 2 MODELS 165 Heat Only 240011941 REV B 03 31 2018 ...
Page 67: ...63 APPENDIX A WIRING DIAGRAMS A 3 MODELS 150 Combi 240011941 REV B 03 31 2018 ...
Page 68: ...64 APPENDIX A WIRING DIAGRAMS A 4 MODELS 205 Combi 240011941 REV B 03 31 2018 ...
Page 69: ...65 NOTES 240011941 REV B 03 31 2018 ...
Page 70: ...66 NOTES 240011941 REV B 03 31 2018 ...
Page 81: ...9 125 WITH ZONE CIRCULATOR PUMPS 125 with Zone Circulator Pumps PN 240011430 REV G 03 31 18 ...
Page 84: ...12 125 WITH ZONE VALVES PIPING DIAGRAM 125 with Zone Valves PN 240011430 REV G 03 31 18 ...
Page 90: ...18 165 with Zone Valves 165 WITH ZONE VALVES PIPING DIAGRAM PN 240011430 REV G 03 31 18 ...
Page 94: ...22 150 205 WITH ZONE PUMPS WIRING DIAGRAM 150 205 With Zone Pumps PN 240011430 REV G 03 31 18 ...
Page 102: ...30 MODEL 125 Heat Only 125 HEAT ONLY WIRING DIAGRAM PN 240011430 REV G 03 31 18 ...
Page 103: ...31 MODEL 165 Heat Only 165 HEAT ONLY WIRING DIAGRAM PN 240011430 REV G 03 31 18 ...
Page 104: ...32 MODEL 150 Combi 150 COMBI WIRING DIAGRAM PN 240011430 REV G 03 31 18 ...
Page 105: ...33 MODEL 205 Combi 205 COMBI WIRING DIAGRAM PN 240011430 REV G 03 31 18 ...
Page 110: ...38 Low Water Cutoff Detail LOW WATER CUTOFF NO NO YES PN 240011430 REV G 03 31 18 ...
Page 111: ...39 NOTES PN 240011430 REV G 03 31 18 ...
Page 112: ......
Page 115: ......