Grounding
terminal
Board
diagram
Please follow below installation steps
Please check the following items before installation. If any missing, please contact the dealer.
Power adapter
Ethernet Extender
1 pcs
MIT hanger
2 pcs
User mannal
1 pcs
1 pcs
1) Please turn off the signal source and the device's power, installation with power on may damage the
device;
2) Check if the network cable and other transmission line is occupied by other device;
3) Use a network cable to connect RJ45 port of SV-Unit and Ethernet switch, use another network cable
or coaxial cable to connect EOC port of SV-Unit and EOC port of IPC-Unit;
4) Use a network cable to connect IP camera with RJ45 port of IPC-Unit;
5) Check if the installation is correct and device is good, make sure all the connection is reliable and
power up the system;
6) Make sure the network is normal.
This Ethernet extender consists of one SV-Unit and one IPC-Unit. It can transfer Ethernet signal from
IPC-Unit to carrier signal and extend it to SV-Unit through coaxial cable or network cable. Then it
transfers carrier signal to Ethernet signal
long
distance Ethernet signal,
security network surveillance and network transformation
project where coaxial cables and ethernet cables are arranged mixed.
. It can fully satisfy the transmission requirements of
and be widely used in
Feature
The equipment consists of two parts: SV-Unit and IPC-Unit. SV-Unit has 12V DC port, one RJ45 input
port and two output ports: BNC and RJ45; IPC-Unit has two input ports: BNC and RJ45, one RJ45
output port and one 12V DC port;
Adopt advanced transmission technoloy to transmit Ethernet signal up to 1200m through coaxial
cable and transmit Ethernet signal up to 700m through network cable;
Ethernet delay less than 1ms; meet point to point application;
Standard: IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX;
Protection: excellent circuit isolation protection, superior product anti-thunder , anti-satic and anti-
interference;
Appearance: durable and delicate, meet MIT rack installation standard, working temperature: 0℃~
55℃;
Installation: Plug-and-play, no setting required.
Ethernet
Extender
User Manual
Caution
1
2
1)
distance!
2) BNC connector and RJ45 port of the equipment can't be used at the same time!
Please use 75-5 standard or above coaxial cable and Cat5e/6 cable to get the longest transmission
Ethernet Extender
Instruction:
IPC left board
VerB 1.
1
Grounding
terminal
EOC
IPC right board
SV left board
SV right board
Device must be connected with lightning protection grounding; otherwise protection level will reduce;
please use above No.20 wire to connect the grounding terminal.
Caution
EOC
LED Status
RJ45 input/output port
EOC RJ45
Yellow Light
Green Light
Yellow /Green Light
Flash
/
Indicate
communication
/
On
Indicate power
supply normal
Indicate cable
connected
Indicate cable
connection normal
Application
12V
12V
Co
axia
l C
ab
le
IP C
ame
ra
DC1
2V
Ca
t5e
/
6
LC
D
NVR
IP C
ame
ra
IPC-u
nit
Ca
t5e
/6
Eth
ern
et S
witc
h
Ca
t5e
/6
SV-u
nit
SV-u
nit
IPC
-unit
DC1
2V
DC1
2V
DC1
2V
Power
Power
Installation
steps