     The product           

                                                

1pc

  

     

User manual                                                          1pc

     

1

.

Check grounding resistance that should meet the specification before connection the 

device to system.
2

Connect protector on the front of the protected device 

,

it

 

must be connected reliably.

3

Connect the device ground wire to protection ground strap keeping in the shortest 

possible distance.

Note

:

1.Protectors have In, Out symbol

,

 connect

 

output

 

to

 

protect

ed

 

device

,

 do

 

not

 

take

 

opposite

Otherwise

 

it

 

will

cause

 

the

 

damage

 

of

 

the

 

protector

 ,

equipment

 

also

 

can

 

not

 

be

 

protected

 .

2.Loss

 

increases

 

by

 

bad

 

connection

 

socket

 

and

 

other

 

factors

should

 

reconnect

 

or

 

replace

 

protector

3. The

 

user

 

can

 

not

 

disassemble

 

the

 

various

 

parts

 

of

 

the

 

protector

avoid

 

damaging

affect

 

the

 

normal working.

Installation steps

      

The product is a single channel network signal surge protector according to IEC61643-21:2000 design 

standard. The device rated working voltage is 5V, the max continuous running voltage is 6V, limited voltage 

less  than  20V,  it  has  multi  level  protection  function,  high  capacity,  low  limited  voltage,  quickly  response, 

low  insertion  loss  and  so  on  .It  is  applicable  for  computer  network  signal  ,  Hub,  network  switch,  network 

and  so  on  as  whole  monitoring  system  accurate  overvoltage  protection,

  making  it  is  safe  from  induced 

overvoltage ,operating over-voltage and electrostatic discharge caused damage.

Features

:

Application

Reference standard: IEC61643-21:2000;
Protection signals: Ethernet signal,10/100Mbps;
Function  :  Multi  function  and  multi  level  over  voltage  protection,  high  capacity,  low  limited 
voltage, quickly response, low insertion loss;
Grounding: Extension cable directly connect with ground wire;
Appearance  design:  identification  clearness,  easy  recognition,  whole  aluminium  outer 