This is a default allocation. The capacity can be re-allocated using the Integrated Configuration Tool.
Minimum supported board levels for the PXNplus CPU board
If the controller board contains a 4 or 5 digit numeric date code, it can be used with the PXNplus CPU board. If
the controller board shows a 2-digit alpha date code, refer to the table below for the minimum level required.
Offline alarm history capacity
2,000
1
Picture Perfect 3.x, 2.x
Badge capacity
145,000
Offline badge history capacity
5,000
1
Table 3. Minimum board level required for use with the PXNplus CPU board
Board
Part number
Date code
1
1.
The first letter identifies the month where A=January, B=February, and so on. The second letter identifies the year where Z=1999,
Y=1998, and the sequence continues with each previous letter representing the previous year.
Power/Communications
110064001
IZ September
1999
2RP
110063001
DY
April 1998
2SRP
110101501
No minimum level required
8RP
110100501
FY
June 1998
20DI
110072003
IX
September 1997
16DO
110071001
GZ
July 1999
16DOR
110078001
No minimum level required
Backplane
110061001
Revision C
PXNplus CPU board
Summary of Contents for M3000
Page 1: ...M3000 Installation Manual P N 460630001H 15JUNE11 ...
Page 10: ...M3000 Installation Manual x ...
Page 39: ...Chapter 3 Power Communications board 29 Figure 11 Wiring modem to M3000 M 5 or serial printer ...
Page 47: ...Chapter 4 PXNplus CPU board 37 Board layout Figure 16 PXNplus CPU board layout ...
Page 58: ...M3000 Installation Manual 48 Board layout Figure 17 2RP reader board layout ...
Page 68: ...M3000 Installation Manual 58 Figure 24 Wiring 2RP door strike external relay ...
Page 72: ...M3000 Installation Manual 62 Board layout Figure 27 2SRP supervised reader board layout ...
Page 82: ...M3000 Installation Manual 72 Figure 19 Wiring 2SRP door alarm contact and exit request ...
Page 84: ...M3000 Installation Manual 74 Figure 21 Wiring 2SRP door strike external relay ...
Page 89: ...Chapter 5 Reader processing boards 79 Board layout Figure 24 8RP reader board layout ...
Page 92: ...M3000 Installation Manual 82 Figure 26 Wiring 8RP to F 2F or Supervised F 2F Readers ...
Page 94: ...M3000 Installation Manual 84 ...
Page 97: ...Chapter 6 Optional DI and DO boards 87 Figure 31 20DI board layout ...
Page 99: ...Chapter 6 Optional DI and DO boards 89 Figure 32 Wiring DI point ...
Page 101: ...Chapter 6 Optional DI and DO boards 91 Figure 33 16DO board layout ...
Page 102: ...M3000 Installation Manual 92 Figure 34 16DOR board layout ...
Page 104: ...M3000 Installation Manual 94 Figure 36 Wiring output device to 16DOR board ...
Page 152: ...M3000 Installation Manual 142 ...
Page 156: ...M5 controller Installation Manual 146 Figure 76 Installing ferrite ...
Page 160: ...M5 controller Installation Manual 150 ...
Page 172: ...M3000 Installation Manual 162 ...