2NM/2NX/2NY/2NZ/2P0/2P6
1-3-83
U641
Comm Time 2
Description
Sets the time-out time for fax transmission.
Purpose
To improve transmission performance for international communications mainly.
Method
1. Press the start key.
2. Select the item to be set.
Display
Description
T0 TIME OUT
Sets the T0 time-out time.
T1 TIME OUT
Sets the T1 time-out time.
T2 TIME OUT
Sets the T2 time-out time.
Ta TIME OUT
Sets the Ta time-out time.
Tb1 TIME OUT
Sets the Tb1 time-out time.
Tb2 TIME OUT
Sets the Tb2 time-out time.
Tc TIME OUT
Sets the Tc time-out time.
Td TIME OUT
Sets the Td time-out time.
Setting: T0 time out
Sets the time before detecting a CED or DIS signal after a dialing signal is sent.
Depending on the quality of the exchange, or when the auto select function is selected at the des-
tination unit, a line can be disconnected. Change the setting to prevent this problem.
1. Change the setting using the cursor right/left keys.
Description
Setting range
Initial setting
T0 time-out time
30 to 90 s
56
2. Press the start key. The value is set.
Setting: T1 time out
Sets the time before receiving the correct signal after call reception. No change is necessary for
this maintenance item.
1. Change the setting using the cursor right/left keys.
Description
Setting range
Initial setting
T1 time-out time
30 to 90 s
36
2. Press the start key. The value is set.
Summary of Contents for P-4030 MFP
Page 7: ...This page is intentionally left blank ...
Page 13: ...This page is intentionally left blank ...
Page 19: ...2NM 2NX 2NY 2NZ 2P0 2P6 5 Installation Guide PF 320 Paper Feeder ...
Page 55: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 2 24 This page is intentionally left blank ...
Page 386: ...2NM 2NX 2NY 2NZ 2P0 2P6 1 5 100 This page is intentionally left blank ...
Page 486: ...Installation Guide PF 320 Paper Feeder Installation Guide ...
Page 487: ...PF 320 㾌㙼 㾌㙼 PF 320 PF 320 PF 320 㪧㪝㪄㪊㪉㪇 㪧㪝㪄㪊㪉㪇䈱 㪧㪝㪄㪊㪉㪇G 㾌 㾌 PF 320 PF 320 ...