USSC Logwood 1261 Owner'S Manual Download Page 1

CAUTION!

Read All Instructions Care-
fully Before Starting The In-
stallation or Operating This
Heater.

DO NOT USE THIS HEATER

IN A MOBILE HOME OR TRAILER

SAVE THIS MANUAL FOR FUTURE REFERENCE

THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE
YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

UNITED STATES STOVE COMPANY

227 Industrial Park Road

P.O. Box 151

South Pittsburg, TN  37380

(423) 837-2100

COMPANY

UN

ITE

D STATES STOV

E

C

S

S

U

Owner

Owner

Owner

Owner

Owners Manual

s Manual

s Manual

s Manual

s Manual

Logwood 1261

85029E

EPA EXEMPT PER

METHOD 28A

TESTED TO

UL 1482

R

U S

Summary of Contents for Logwood 1261

Page 1: ...TAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE UNITED STATES STOVE COMPANY 227 Industrial Park Road P O Box 151 South Pittsburg TN 37380 423 837 2100 COMPANY U NITED STATES STOV E C S S U Owner Owner Owner Owner Owners Manual s Manual s Manual s Manual s Manual Logwood 1261 85029E EPA EXEMPT PER METHOD 28A ...

Page 2: ...tric Drill Bit 1 8 Dia For Sheet Metal Screws Adjustable Wrench Screw Driver Blade Type Gloves Safety Glasses MATERIALS 6 Elbow Collar and Thimble As Required 24 gauge min 1 2 Sheet Metal Screws No 10A x 1 2 6 Diameter 24 gauge black or blued steel Underwriters Laboratories UL Listed Residential Type HT 2100 F Chimney or use a Masonry Chimney in good repair Floor Protector Material R value 2 0 Siz...

Page 3: ...w anyone to use this heater who is unfamiliar with the correct opera tion of the heater 1 2 3 4 5 6 7 8 9 10 11 12 13 14 For further information on using your heater safely obtain a copy of the National Fire Pro tection Association NFPA publication Using Coal and Wood Stoves Safely NFPA No HS 10 1978 The address of the NFPA is Batterymarch Park MA 02269 Disposal of Ashes Place ashes in a metal con...

Page 4: ...ace the stove in your selected location Install stove pipe elbows and thimble as necessary utilizing either a recently cleaned and inspected masonry chimney properly lined or a UL Listed chimney Insure that the damper provided is installed in the flue collar Again check the following illustrations and be sure you have the clearances shown from the heater and the connector pipe to combustible surfa...

Page 5: ... seal the pipe at the chimney Use 3 sheet metal screws at each joint to make the piping rigid It is recommended that no more than two 2 90 degree bends be used in the stove pipe installation as more than two 2 may decrease the amount of draw and possibly cause smoke spillage 1 2 3 4 5 6 7 Chimney Connection MASONRY CHIMNEY The masonry chimney must comply with UL codes Before using an existing maso...

Page 6: ... be connected to a masonry chimney by passing through a combustible wall NFPA Standard 211 allows the following wall pass through systems MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 AIRTIGHT CLEANOUT DOOR FLOOR PROTECTOR COMBUSTIBLE WALL TO HEATER CHIMNEY CONNECTOR CEILING SEE PARTS A B C D AND E OF THIS FIGURE FOR OPTIONS CHIMNEY FLUE FIGURE 8 CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY THRO...

Page 7: ... tor by means of sheet steel support plates on both ends of the chimney section The opening in the combustible wall shall be covered and the chimney section supported on both sides with sheet steel supports which are at least 24 gauge 0 024 in thickness The sheet steel supports shall be securely fastened to wall surfaces on all sides and shall be sized to fit and hold the chimney section Fasteners...

Page 8: ...INIMUM FACTORY BUILT CHIMNEY LENGTH SHEET STEEL SUPPORTS CHIMNEY SECTION CHIMNEY CONNECTOR AIR SPACE 2 IN TWO VENTILATED AIR CHANNELS EACH 1 INCH CONSTRUCTED OF SHEET STEEL PART C FIGURE 8 PART D FIGURE 8 MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 SHEET STEEL SUPPORTS 24 GAUGE MIN THICKNESS CHIMNEY CONNECTOR TO HEATER MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 ...

Page 9: ...rgequantity of coarse salt baking soda or cool ashes on top of the fire in the firebox CAUTION A chimney fire may cause ignition of wall studs or rafters which you thought were a safe distance from the chimney If you have a chimney fire have your chimney inspected by a qualified person before using again Service Hints Do not expect a heater to draw It is the chimney that creates the draft Smoke sp...

Page 10: ...0304 40305 40306 40307 40308 40332 D6 83427 89971 89972 89973 89974 89975 89589 85029 DESCRIPTION REAR LEG FRONT LEG MAIN BOTTOM MAIN SIDE MAIN BACK HEARTH PLATE SLIDING DRAFT PLATE DOOR FRAME DOOR MAIN TOP PIVOTING TOP LID LID SUPPORT LID LIFTER FLUE COLLAR SOLID FLUE DAMPER DOOR PINS HANDLE LATCH NUTS HANDLE EXTENSION HANDLE BRACKET PARTS BAG OWNERS MANUAL QNTY 2 2 1 2 1 1 1 1 1 1 1 2 1 1 1 1 2 ...

Page 11: ...NOTES 11 ...

Page 12: ...EN WRITING ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE BACK OF THE HEATER WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST 1 The PART NUMBER 2 The PART DESCRIPTION 3 The MODEL NUMBER 1261 4 The SERIAL NUMBER UNITED STATES STOVE COMPANY 227 Industrial Park Road P O Box 151 South Pittsburg TN 37380 423 837 2100 www USSTOVE com ...