background image

MODEL USI-2430
HEAT ALARM

120 VAC WITH
9V BATTERY BACKUP

OWNER'S MANUAL

WHAT YOU SHOULD KNOW ABOUT HEAT ALARMS

FEATURES

This heat alarm is powered by 120 VAC and a 9 Volt battery backup source. AC/
DC heat alarms offer added protection in the event of a power failure or a drained
battery.

This alarm may be interconnected with a total of not more than 24 interconnected
devices, i.e., as many as 12 other USI ELECTRIC or UNIVERSAL model smoke
alarms or combination smoke and carbon monoxide (CO) or smoke and carbon
monoxide / natural gas alarms; 5 other initiating alarms which may be a combination
of USI ELECTRIC or UNIVERSAL CO Alarms and Heat Alarms; and six other non-
initiating devices such as USI ELECTRIC Relay Modules

This heat alarm will not attach to the mounting ring if a battery is not in the battery
chamber.

This heat alarm will sound a short beep about once a minute if the battery is weak
or improperly connected.

The green LED indicates that the heat alarm is receiving AC power and is working
under normal operation.

A loud 85 decibels at 10 feet alarm horn will sound to alert you of an emergency.

The test button checks heat alarm operation.

SPECIFICATIONS

Model Number

USI-2430

Electrical Rating

120 VAC, 60 Hz, 50 mA maximum, 9 Volt
battery backup

Interconnect

24 units maximum

Interconnect  with

Up to 5 USI heat alarms or CO alarms and
up to 12 USI smoke alarms and 6 other
non-initiating devices (Relay Modules)

UL Temperature Rating

135

o

F (57

o

C) fixed temperature

UL Maximum Ambient Temperature

100

o

F (38

o

C)

at Unit

Operating Temperature

-10

o

F to 158

o

F (-23

o

C to 70

o

C)

UL Recommended Coverage

2500 square feet (see Note A:)

UL Recommended Spacing

50  feet

Maximum Distance from Wall

25 feet (see Note B:)

Heat alarms are not life safety devices and are not designed to
detect smoke or fire. They are intended to detect temperatures of
135

o

F or more and to provide an additional source of information

that is supplemental to smoke alarms to increase the probability that
an early warning will be provided to increase chances of life and
property safety.

PLEASE READ AND SAVE!

Installer: Please leave this manual with the product.

Visit Us on the Web!

 www.SmokeAlarms.com

Summary of Contents for USI-2430

Page 1: ...wer and is working under normal operation A loud 85 decibels at 10 feet alarm horn will sound to alert you of an emergency The test button checks heat alarm operation SPECIFICATIONS Model Number USI 2430 Electrical Rating 120 VAC 60 Hz 50 mA maximum 9 Volt battery backup Interconnect 24 units maximum Interconnect with Up to 5 USI heat alarms or CO alarms and up to 12 USI smoke alarms and 6 other n...

Page 2: ...dded source of information and supplement smoke alarm installation Some fires are slow smoldering low heat producing or are in a different room than the heat alarm or the heat from the fire may bypass the alarm This heat alarm will not always detect this type of fire The push to test button accurately tests all heat alarm functions For temperatures that are below minus 10o F use a handheld hair dr...

Page 3: ... 3 EXISTING HOMES NEW CONSTRUCTION HOMES ...

Page 4: ...smooth ceiling spacing reduced to no more than half of the listed spacing when measured at right angles to a solid joist DO NOT INSTALL HEATALARMS In areas with high humidity like bathrooms shower rooms or areas near dishwashers or washing machines Install at least 10 feet 3m away from these areas if possible Near air returns or heating and cooling supply vents fans decorative objects window moldi...

Page 5: ...re you will install this unit at the circuit breaker or fuse box before beginning installation Failure to turn off the power before installation may result in serious electrical shock injury or death TAMPER LOCKING PIN To make your heat alarm somewhat tamper resistant a locking pin has been provided Using this pin will deter children and others from removing the alarm from the mounting ring To use...

Page 6: ...S 2790 SS 2785 SS 2895 HD 130 USI 1103 USI 1203 USI 1204 USI 1208 Part USI 1209 USI 1213 USI 2430 USI 3204 USI 5204 USI 5208 USI 5213 USI 7385 USI 7390 USI 7485 USI 7490 CD 9385 CD 9390 CD 9485 CD 9490 CD 9795 USI 7795 AND USI 960 RM 100 Relay When any one of these interconnected models goes into alarm it will trigger the corresponding alarm within the interconnected system with respect to their s...

Page 7: ...s event initiated the alarm All other alarms remain silent Interconnected smoke alarms heat alarms and relay modules will only respond if a smoke alarm event or heat alarm event initiates the alarm All CO and Natural Gas alarms remain silent Note that alarms without battery backup will not respond during an AC power failure NOTE Relay Modules USI 960 will not respond if a CO or Natural Gas alarm e...

Page 8: ... failure NEVER use an open flame of any kind to test this unit You might accidentally damage or set fire to the unit or to your home The built in test switch accurately tests the unit s operation as required by Underwriters Laboratories Inc UL BACKUP BATTERY REPLACEMENT Disconnect AC power before changing battery Shock hazard exists if AC power is miswired The heat alarm uses a 9 Volt battery The ...

Page 9: ... all right to do so 9 NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED PROTECTION For your information the National Fire Protection Association s Standard 72 reads as follows 11 5 1 One and Two Family Dwelling Units 11 5 1 1 Smoke Detection Where required by applicable laws codes or standards for the specified occupancy approved single and multiple station smoke alarms shall be installed as follows 1...

Page 10: ...Customer Service at 1 800 390 4321 Ext 238 for current postage and handling fees USI DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW SHALL EXTEND BEYOND THE TERM OF THIS WARRANTY UNLESS SUCH LAW OTHERWISE PROVIDES USI SPECIFICALLY...

Reviews: