background image

OPERATING MANUAL

UDC PORTABLE SPOT CURE  

LED LIGHT SOURCE

Summary of Contents for Midori UDC365

Page 1: ...OPERATING MANUAL UDC PORTABLE SPOT CURE LED LIGHT SOURCE...

Page 2: ...IMITED WARRANTY 21 SECTION 7 REGULATORY 22 SECTION 8 MANUFACTURE CONTACT INFORMATION 23 Thank you for purchasing the Midori UDC Portable Spot Cure series LED Light Source utilizing solid state UV tech...

Page 3: ...n UV WARNING UV emitted from this product Avoid eye and skin exposure to unshielded product Do not dispose of this product as unsorted municipal waste Prepare this product for reuse or separate collec...

Page 4: ...pt to assure damage has not occurred during shipment Verify compatibility of all components and accessories used with the UDC PSC unit Since the UDC PSC unit uses proprietary components there are no u...

Page 5: ...seconds This recorded time is stored until the batteries are removed WARNING Upon power up the UDC UV drives the LED to full intensity Avoid looking directly at the LED when turning ON Preset Timer Bu...

Page 6: ...ystem Power Source Battery Powered 2 x RCR123A Battery Type 2 Lithium Ion RCR123A 3 7V 750mAh Minimum Battery Life for Continuous Runtime 80 Minutes Battery Charge Time 2 Hours Battery Recharge Cycles...

Page 7: ...25 450 475 500 525 550 365nm 405nm REF Relative Normalized Output Nominal Peak Wavelength 365nm 405nm Working Distance FWHM Spot Size Relative Intensity Irradiance mw cm 2 UDC365 Irradiance mw cm 2 UD...

Page 8: ...02 RCR123A Li Ion Battery Order Code 9500038 UDC405 Spot Cure Pak Basic Kit Configuration QTY Item Product ID Description 1 T130 5015 UDC405 UDC405 UAI GB PSC 1 5002491 UPC 02 2 bay Smart Charger 4 50...

Page 9: ...ve terminal of each battery should be in contact with the spring on each circuit board refer to figure 3 Attach the hatch door then rotate the locking knob clockwise until the line on the knob is poin...

Page 10: ...the 4 second or 8 second timer buttons refer to figure 5 and 6 WARNING Upon power up the UDC PSC operates the LED to full intensity Avoid looking directly at the LED when turning ON 2 Pressing any but...

Page 11: ...ght 40g Manufacturer Part Number Tenergy Item 34253 WARNING USE ONLY APPROVED BATTERIES Use only pairs of fully charged batteries Do not mix newly charged and depleted batteries Never mix rechargeable...

Page 12: ...ing detected CHARGE will show on the status screen 4 When charging is done will be displayed on the digital screen of the LCD 5 Remove battery after it s fully charged Reverse Bad Cell Short Circuit R...

Page 13: ...ve Deactivate LiFePO4 Mode D Charging slot 1 E Charging slot 2 F Micro USB input port 5V DC 2A Charger Features Manufacturer supplied charger is a 2 bay battery smart charger with MCU control which fe...

Page 14: ...tatus Display Backlit LCD Built In Protections Short circuit Reverse Polarity Bad Cell Detection Safety Timer Compatible Rechargeable Battery Ni MH Ni Cd AA AAA AAAA CID Sub C IMR Li ion LiFeP04 18650...

Page 15: ...unit and recycle or dispose the batteries safety 9 This appliance is not recommended for children under 8 years old or persons with reduced physical sensory or mental capabilities Adult supervision i...

Page 16: ...NOT available for NIMH and NICO Note 2A USB power source is needed to charge 2x Li ion battery at 1000mA speed setting Tip It is safe to use 1A current option for Li ion IMR and LiFeP04 batteries as...

Page 17: ...harging is failed See more in Reverse Bad Cell Short Circuit C Battery Gauge Indicates the selected charging slot 1 or 2 Charging starts and the first block will be flashing Charging is finished and a...

Page 18: ...e UDC PSC unit and will void the product warranty Use caution when cleaning the UDC PSC unit some methods may be harmful and could result in extensive damage Manual cleaning is the recommended method...

Page 19: ...UDC PSC unit CAUTION Do not allow the UDC PSC unit to remain in liquid cleaning solution for prolonged period of time In addition thoroughly dry the battery hatch door seal around the O ring with comp...

Page 20: ...eries are the same type and freshly charged UDC UV Light Output Flashing Battery charge is low Replace batteries with freshly charged batteries This is normal behavior indicator when the battery charg...

Page 21: ...nty repairs will be warranted to be free from defects in materials and workmanship for a period of ninety 90 days from the date of the invoice This limited warranty does not cover the breakage or fail...

Page 22: ...tested to and found in conformance with the following standards EN50581 2012 2006 95 EC 93 68 EEC Low Voltage Directive IEC 62471 2006 LED Photobiological safety lamp standard categorized as Risk Gro...

Page 23: ...CONTACT INFORMATION SECTION 8 Manufactured and Serviced by Ushio America Inc 5440 Cerritos Ave Cypress CA 90630 USA Tel 1 714 236 8600 Fax 1 714 229 3180 Toll Free 1 800 838 7446 Customer Service cus...

Page 24: ...Form No UDC UV 0321 5440 Cerritos Avenue Cypress CA 90630 2021 UshioAmerica Inc All rights reserved Made in USA...