Operation and Function
03/19
Fl Set XL
28
8.2
Status display
Green
(duration)
No leak has been detected yet.
Yellow
(Duration)
Minor permanent water withdrawal or a small leak was
detected over a long period of time. The check indicator
(12) is also permanently yellow.
(for more information see chapter 9.2.2 "Permanent
yellow status display")
Yellow
(flashes)
Green
(flashing)
A leak test is carried out (approx. 5 minutes). The check
indicator (12) also flashes yellow.
(for more information see chapter 8.1.4 "Test mode")
The water supply was automatically interrupted by
Fl.
Red (duration)
Permanent water withdrawal or leakage which exceeded
the preset maximum flow duration (30 min. ex works)
was detected. The alarm display (13) is permanently red.
(more on this in chapter 9.2.1 "Status display
permanently red")