1.  Read all instructions carefully before operation. 
2.  Avoid pinched o-rings during installation by applying (provided with install kit) NSF 

certified lubricant to all seals. 

3.  This system is not intended for treating water that is microbiologically unsafe or of 

unknown quality without adequate disinfection before or after the system. 

US Water Systems 
1209 Country Club Road 
Indianapolis, IN 46234 
1-800-608-8792 
WWW.USWATERSYSTEMS.COM

 

Owners Man

ual

 

Summary of Contents for FSF-150

Page 1: ...id pinched o rings during installation by applying provided with install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or o...

Page 2: ...y damage or personal injury Be sure to check the entire unit for any shipping damage or missing parts Also note damage to the shipping cartons Contact US Water Systems at 1 800 608 8792 for all damage...

Page 3: ...and ordinances Use only lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over...

Page 4: ...4 Specifications...

Page 5: ...make product improvements which may deviate from the specifications and descriptions stated herein without obligation to change previously manufactured products or to note the change Peak flow rates a...

Page 6: ...5 8 OD drain line is needed for the valve drain Sizing Requirements Water Pressure The water system must have a pump large enough to deliver the recommended backwash rate with a minimum pressure at t...

Page 7: ...ut the filter in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for wa ter damage A 120 volt electric outlet to plug the includ ed transformer...

Page 8: ...ing plumbing should be free from lime and iron buildup Piping that is built up heavily with lime and or iron should be replaced LOCATION OF FUSION NLT TANK AND DRAIN The Infusion tank should be locate...

Page 9: ...tank and pour slow enough to keep from plugging the hole A helper may be needed to hold the funnel during the filling process It is recom mended that a dust mask and safety goggles be worn to prevent...

Page 10: ...s then turning the basket clockwise to lock it in place Place the upper basket over the distributor tube and push the valve on the tank Thread the valve on the tank by turning it clockwise Be sure not...

Page 11: ...AND OUTLET PIPING TO MAINTAIN GROUNDING WHEN APPLICABLE Any solder joints being soldered near the valve must be done before connecting any piping to the valve Always leave at least 6 152 mm between t...

Page 12: ...f running the drain line more than 20 ft overhead it is recommended to increase the hose size to 3 4 A DIRECT CONNECTION INTO A WASTE DRAIN IS NOT RECOMMENDED A PHYSICAL AIR GAP OF AT LEAST 1 5 SHOULD...

Page 13: ...ter tap nearby remove the faucet screen open the faucet and let water run a few minutes or until the system is free of any air or foreign material resulting from the plumbing work 7 Make sure there ar...

Page 14: ...14 Filter Installation...

Page 15: ...drain line flow Allow the water to run for 3 4 minutes or until the water is clear 6 The valve will automatically advance to the SERVICE position after the RINSE cycle is complete Open the outlet valv...

Page 16: ...ault value is OFF This should not be changed REGEN TIME This setting determines the time of day to perform a scheduled regenera tion The normal regen time for a filter is 12 00 AM Settings Press SETIN...

Page 17: ...nd Time page for 5 seconds Then it will continually scroll through all of the system diagnostic display pages Depending on the Valve Type some pages will not be displayed To manually scroll through th...

Page 18: ...normal operation the bypass is open with the on off knobs in line with the inlet and outlet pipes To isolate the filter simply rotate the knobs clockwise as indicated by the word BYPASS and arrow unti...

Page 19: ...0048 TOP CONE D 1 25020041 844 TANK 75 E 1 25020042 948 TANK 100 E 1 25020043 1054 TANK 150 E 1 25010058 1252 TANK 200 E 1 25030007 1465 TANK 300 E 1 50010005 DISTRIBUTOR 1X54 F 1 REPLACEMENT PARTS FI...

Page 20: ...20 Filter Exploded View...

Page 21: ...BOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP D 2 60010046 BYPASS SS CL...

Page 22: ...TOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032 INJECTOR SET 2 BLUE 6001013...

Page 23: ...A20 1 5056063 O Ring 78 74 5 33 A21 1 26010103 O Ring 25 3 55 A22 1 7060007 Valve Bottom Connector A23 1 13000426 Screw ST2 9X13 Large Washer A24 2 5031022 O Ring 32 3 A25 1 5031021 O Ring 18 3 A26 1...

Page 24: ...24 Power Head Exploded View...

Page 25: ...0426 Screw ST2 9X13 Large Washer A24 2 5056139 Washer 3x13 B09 1 5030007 BNT85 Main Gear B10 1 5030005 BNT185 Housing B11 1 5031017 BNT85HE Brine Gear Downflow B12 1 5010023 Magnet 3 2 7 B13 1 5056141...

Page 26: ...k if central tube is cracked or o ring is damaged Replace faulty parts 8 Internal valve leak Replace valve seals spacer and piston assembly 1 Iron or scale build up in line feeding unit Clean pipes 2...

Page 27: ...27 Pressure Differential Gauge Installation...