Modemulator User Guide
Page
52
of
113
A "Dialback:" instead of "Login:" prompt will be displayed. The Dialer should type the phone
number containing the Dialer's IP address (shown in the answer Modemulator's dialing directory).
The dialing Modemulator will display "Dialback Security" and disconnect. Both Modemulators will
restart their Listener port. The answering Modemulator will wait S44 (default=15) seconds, and
then dial the requested phone number (translated to IP address).
Example:
answer's directory contains: 5551234 8888 172.17.2.1
Dialer calls answer Modemulator
at "Dialback:", Dialer types 5551234
answering Modemulator disconnects and dials back to 172.17.2.1:8888
If the Dialer is requesting Remote Command Mode (see the
), then after the Dialback
is connected, the "Login:" prompt will be displayed, requiring an Administrator's password.
{F0 * Allow Forwarding of Configuration Commands to Analog Modem (default)
Normally, an AT command containing a dial string with a phone number not found in the dialing
directory will be forwarded in its entirety to the analog modem attached to the modem port.
{F1 * Disable Forwarding of Configuration Commands to Analog Modem
This command will cause only the dial string portion of the AT command (not the configuration
commands) to be sent to the attached analog modem.
{I= * Program Caller ID
This must be the last command in the AT command string.
Enter the Caller ID string to be sent to the Listener during Modemulator handshake protocol. The
CID string may be up to 23 numeric (0-9) digits. Attempting to enter a non-numeric character or
more than 23 digits will return
ERROR
.
Example:
AT{I=18005551234
To clear the Caller ID string, enter
AT{I=<Enter>
{J0 * Normal Security and Login Banners (default)
The Security and Login banners will remain separate.