![US Robotics USR3520 User Manual Download Page 38](http://html1.mh-extra.com/html/us-robotics/usr3520/usr3520_user-manual_1063482038.webp)
Modemulator User Guide
Page
38
of
113
E1 * Command Echo ON (default)
Enable local echo of typed characters.
F0 * Local Online Echo ON
Enable local echo of typed characters in a data connection.
This is sometimes known as half-duplex mode.
F1 * Local Online Echo OFF (default)
Disable local echo of typed characters in a data connection.
This is sometimes known as full-duplex mode.
H * Hang Up
This must be the last command in the AT command string.
Disconnect the local TCP client from Remote Command Mode (see the
) and cause
both Modemulators to report
NO CARRIER
.
I1 * Display Checksum
Display the Modemulator firmware's 4 digit hex checksum (used mainly by tech support).
Example:
This command will not be forwarded to the analog modem.
ATI1
CE58
OK