24
DS1375-020E
To define the Provider, specify the following parameters:
—
Provider Name:
name of the Provider that provides the service
—
URL Template:
it represents the command sent to the provider to send an SMS (every service provider has its
own); this string will be specified by the Provider and usually features the following fields:
@@UserName@@: Username configured for this connection
@@Password@@: Password configured for this connection
@@PhoneNumber@@: Telephone number of the SMS recipient
@@Text@@: Text of the SMS message
—
User:
user of the account set during the registration to the chosen provider
—
Password:
password of the account set during the registration to the chosen provider.
Once the SMS Provider has been saved, it will be possible to view the Provider on the Provider List page.
To send an SMS, select the menu item Messages
→
SMS,
Enter the following data:
—
Provider Name:
select the required Provider among those previously defined.
—
List of recipients:
enter one or more mobile telephone numbers, separated by “,”
—
Text of the Message:
write the text to be sent via SMS, up to a maximum of 160 characters.
Send by confirming with key
.
Still from the Settings section of the SMS page, following the submenu item SMS Report, it will be possible to see
the log of the SMS messages sent on a system level.
This list indicates for each SMS sent:
—
Date/Time:
date and time at which the SMS was sent.
—
Recipient:
telephone number to which the SMS was sent.
—
Content:
preview of the initial part of the SMS.
—
Outcome:
outcome of the transmission.
—
User:
user of the system that sent the SMS.
—
Actions:
it is possible to forward an old message to a new recipient.
11.6
EXTERNAL IP VIDEO STATIONS
The service requires activation of a licence for
Video extensions
/
Urmet VPE Ref. 1375/31x
.
iPerTAlk allows the direct management of Urmet IP Outdoor Stations of the Ref.1375/821 and 1375/822 range).
The calls can be managed from any telephone terminal both in audio/video and audio only mode, moreover the
gates can be operated through DTMF codes: * or 1 for SE and # or 2 for SE2.
A maximum of 6 buttons can be configured for all video door phone outdoor station models.
Summary of Contents for iPerTAlk 1375
Page 98: ...98 DS1375 020E...
Page 99: ...99 DS1375 020E...