background image

 

                                                                                    

 

 
 
 

Guide to replacing the Digivoice 1038/16 Call Module 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Page 5 

 

Retrieving programming information from the existing 1038/16

 

Swapping the existing 1038/16 

 

Programming the new 1038/16 

 

Page 1 

 

Page 4 

 

Page 7 

 

1038/16 voltages 

 

Summary of Contents for DIGIVOICE K-Steel 1038/16

Page 1: ...o replacing the Digivoice 1038 16 Call Module Page 5 Retrieving programming information from the existing 1038 16 Swapping the existing 1038 16 Programming the new 1038 16 Page 1 Page 4 Page 7 1038 16 voltages ...

Page 2: ...ing button on the rear of the 1038 16 call module You will see Use the and buttons to select then press You will see this screen Make a note of the current selection and then press At each of the subsequent screens make a note of the current selection and press to move to the next screen After noting the existing PASSWORD press and hold for four seconds until you exit the programming mode 1 ...

Page 3: ...anged to 1067 To enter either password you must first press 00 You will then see Enter the Caretaker s password then press Important note If the 1038 16 which is to be replaced is part of a complex installation with main and secondary call modules AND it is not possible to retrieve the existing programming information then you must contact Urmet Technical Support An example of a complex installati...

Page 4: ...e the and buttons to select then press You will see Press and hold for four seconds to exit the programming mode The existing code used to open the door will appear here instead of 00000000 Make a note of this code 3 ...

Page 5: ...this gap is not filled then there will be no surface for the frame holder gasket to seal against Mechanical installation details for K Steel entry panels are available on request from technical urmet co uk Damage caused by water ingress due to incorrect installation of the entry panel is not covered by the manufacturer s warranty Do not simply un plug the 1038 16 and plug in the new part re using ...

Page 6: ...nformation into the new product using the and buttons When you have finished press and hold the button to exit programming A MAIN panel is one which calls ALL apartments in a system A SECOND panel is one which calls only a specific group of apartments in a system Each panel in a system must have a unique code In a system with only one panel it is not necessary to change the default code It was pos...

Page 7: ...rmal choice Make a selection and press Use the and buttons to select and use the button to increase the time Use the and buttons to select OK and press Note that in some systems the lock output triggers an access control system which in turn controls the lock time In this case set the 1038 16 lock time to 1s To choose the default value press To choose the default value press To choose the default ...

Page 8: ...reat Notley Essex CM77 7AA Tel 01376 556010 Fax 01376 567874 www urmet co uk www urmetmobile com Change as required and press To finish programming press and hold the button until you see 7 Note there is no need to swap any IC s from the old 1038 16 unless there are many names in the directory All of the apartment numbering information is held in the 4 user decoders and not in the 1038 16 For deta...

Reviews: