POWER SUPPLY UNIT WITH CIRCUIT BREAKER Ref. 1038/20

FEATURES - TECHNICAL SPECIFICATIONS

POWER SUPPLY UNIT WITH CIRCUIT BREAKER

Ref. 1038/20

POWER SUPPLY UNIT WITH CIRCUIT BREAKER 
Ref. 1038/20 

FEATURES

Power supply unit with circuit breaker Ref. 1038/20 provides the 
following features:

• 

Supplies power to grouped DIGIVOICE devices.

• 

Supplies power to voice lines for one or more calling devices 
(entrance modules, guard door switchboard stations, etc.).

• 

Supplies power to data line.

• 

In the event of a data line short circuit, the circuit breaker 
automatically isolates the fault and ensures that the remaining parts 
of the system can continue to operate.

• 

Three LEDs indicate power supply unit operating status and provide 
diagnostic error signals.

DESCRIPTION OF TERMINALS

Mains terminals

0  

Mains input

230  

Mains input, 230Vac

Logic and data power supply terminals

M1  

Master power supply unit confi guration input

M2  

Master power supply unit confi guration input

+V  

Logic power supply output, +24Vdc

0V  

Logic power supply output, 0Vdc

+VT  

Logical backup power input

0VT  

Logical backup power input

DU  

Outgoing data line

DE  

Incoming data line

0D  

Data line ground

Voice line power supply terminals

+F  

Voice line power supply output, +33Vdc

0F  

Voice line power supply output, 0Vdc

+FT  

Audio backup power input

0FT  

Audio backup power input

TECHNICAL SPECIFICATIONS

Power supply voltage:  

230 Vac ±10%

(+V, 0V) Logic output voltage:  

24 Vdc ±5% 700 mA

(+F, 0F) Logic output voltage:  

33 Vdc ±5% 65 mA

Data line (DU, 0D)
output voltage: 

(only for units confi gured as Master)

   

24V -7% to 5%

Service temperature range:  

-5 to 45 °C

LOGIC POWER V, 0V

The power supply unit is sized for a typical system confi guration 
consisting of one entrance module with directory Ref. 1038/15 and 35 
fourport decoders Ref. 1038/34.
Complex systems can be set up using two or more power supply units, 
each of which supplies a 

separate 

group of devices through output 

terV, 0V.

 Never connect two or more power supply units 

in parallel.

• 

Each power supply unit Ref. 1038/20 can be connected to a 
maximum of 

70 Load Units

 (LUs).

VOICE LINE POWER F, 0F

The power supply unit can supply one or more calling devices.

In systems with a single voice line

, the speech signal power supply 

unit can also be used to supply multiple entrance panels.

In systems with two voice lines

, the speech signal power supply unit 

can be used to supply the voice line of a 

SINGLE 

entrance panel.

For the remaining entrance panels, use additional speech signal power 
supply units Ref. 1038/25.
In both cases, see the system diagrams provided in the Integrated 
Systems Technical Manual.

DATA LINE POWER SUPPLY DU, 0D

The power supply unit can supply the data line for the entire system. In 
the event of a malfunction, the circuit breaker will automatically isolate 
the fault.
However, 

only one of the power supply units Ref. 1038/20 in the 

system must supply the data line

. The power supply unit used for 

this purpose is referred to as the MASTER unit. All other power supply 
units are referred to as SLAVE units. A power supply unit is confi gured 
as the MASTER by connecting its terminals M1 and M2 together.

Notice

: The data reference ground (0D) of all SLAVE power supply 

units must be connected to terminal 0D on the MASTER power supply 
unit using a dedicated conductor. For examples of wiring layouts, see 
the Integrated Systems Technical Manual.

DATA LINE ISOLATION

In the event of a short circuit on the data line, the power supply unit 
circuit breaker isolates the fault to ensure that all remaining devices 
can continue to operate.

Case A

If the fault occurs on the outgoing data line connected to a riser 
cable power supply unit, only the devices in the secondary riser cable 
concerned will be isolated. The remaining portions of the system will 
continue to operate:

SHORT CIRCUIT

DU
DE

SLAVE

SLAVE

DU
DE

MASTER

DU
DE

ISOLATED

DU
DE

= ISOLATED 
 1038/20

= OPERATING 
 1038/20

DU
DE

DU

ON

DE

Sch. 1038/20

180 mm

(10 DIN modules)

75 mm

96

 mm

WARNING: Be sure to follow the instructions indicated in the 
section headed “Installation Requirements”.