Emergency Situations

 

 

Error 11 

 

Software version 

inconsistent 

Call installation for repair. 

 

Error 12 

 

Multi master 

Restart all batteries 

 

Error 13 

 

MOS 

over 

temperature 

Power  off  the  battery  and  turn 

on  the  battery  after  30-40 

minutes 

 

NOTE: 

 

In the case of parallel mode or work mode, if Protection 09 appears and the power button 

is pressed 5 times within 10 seconds, the BMS will be forced to turn on MOS of discharge so 

that the battery voltage can be detected by the inverter and the battery can be charged. 

5.

 

Emergency Situations

 

URE cannot guarantee the absolute safety of MA1-BAT at all times. 

Fire 

 

In case of fire, make sure that the following equipment is available near the system. 

 

SCBA  (self-contained  breathing  apparatus)  and  protective  gear  in  compliance  with  the 

Directive on Personal Protective Equipment 89/686/EEC.   

 

Novec 1230, FM-200, or dioxide extinguisher. 

NOTE: ABC extinguishers are not effective when the battery pack is on fire. 

Batteries may explode when heated above 150

°

C. If possible, move the battery pack to a safe 

area before it catches fire. 

Leaking Batteries

 

If  the  battery  pack  leaks  electrolyte,  avoid  contact  with  the  leaking  liquid  or  gas.  If  one  is 

exposed to the leaked substance, immediately perform the actions described below: 

 

Inhalation

: Evacuate the contaminated area, and seek medical attention. 

 

Contact  with  eyes

:  Rinse  eyes  with  flowering  water  for  5  minutes,  and  seek  medical 

attention. 

 

Contact  with  skin

:  Wash  the  affected  area  thoroughly  with  soap  and  water,  and  seek 

medical attention. 

Summary of Contents for MA1-BAT

Page 1: ...User Manual Battery Module MA1 BAT V01 ...

Page 2: ......

Page 3: ..._________________________ United Renewable Energy Co Ltd Page 1 of 12 IMPRINT IMPRINT United Renewable Energy Co Ltd Tel 886 3 5780011 Fax 886 3 5781255 Add No 7 Li Hsin 3rd Rd Hsinchu Science Park Hsinchu 30078 Taiwan E mail Ess sales urecorp com ...

Page 4: ...This manual is under the copyright of United Renewable Energy Co Ltd with all rights reserved Please keep the manual properly and operate in strict accordance with all safety and operating instructions in this manual Please do not operate the system before reading through the manual Version Information Version Date Content V01 June 24th 2019 First edition ...

Page 5: ...nt IMPRINT 1 Copyright Statement 2 Version Information 2 Content 3 1 Safety Precautions 4 2 Introduction 4 Features 4 Specifications 5 3 Switch On Off and Display 5 Switch On Off 5 LED Display 5 4 Error and Protection Code 6 Protection Code 6 Error Code 7 5 Emergency Situations 8 6 Warranty 9 Warranty 9 Limitation of Liability 9 ...

Page 6: ...hin 0 C 35 C range Please avoid contact with corrosive substances and keep its distance from fire and heat source The battery SOC is 30 before shipment from the factory For batteries that will not be used for a long time they should be fully charged and discharged at least one time every 6 months Do not install the battery in any environment of temperature below 10 C or over 50 C and humidity over...

Page 7: ...Off System shall be turned on in the correct sequence to avoid any damage Figure 2 MA1 BAT Switch Switch on Pressing the power button for about 2 4 seconds The BMS will start up The LED display and power button will light up as well Switch off Pressing the power button for more than 5 seconds the battery modules will be turned off Figure 3 LED Display LED Display In normal condition LED display in...

Page 8: ...tandby Green light flickering 1 s Work Green light flickering 10s SOC 5 5 SOC 25 25 SOC 50 50 SOC 75 75 SOC 95 SOC 95 4 Error and Protection Code Protection Code LED Ring Protection Code LED Display Description Green light flickering every 3 seconds 1 Temperature difference 3 High temperature 4 Low temperature discharge 5 Over current charge 6 Over current discharge ...

Page 9: ...ardware error Wait for automated recovery In case problem is not resolved call in for repair Error 03 Hardware error Error 05 Hardware error Error 06 Circuit Breaker Open Close circuit breaker after shutting down the battery system Error 07 DIP difference Keep consistence of DIP switches then restart the system Error 08 LMU Disconnect slave Reconnect the communication cable Error 09 SN missing Ent...

Page 10: ...re In case of fire make sure that the following equipment is available near the system SCBA self contained breathing apparatus and protective gear in compliance with the Directive on Personal Protective Equipment 89 686 EEC Novec 1230 FM 200 or dioxide extinguisher NOTE ABC extinguishers are not effective when the battery pack is on fire Batteries may explode when heated above 150 C If possible mo...

Page 11: ... accordance with the user manual and the URE Installation Manual are covered by the warranty Any violation of this manual may void the warranty Limitation of Liability Any product damage or property loss caused by the following conditions URE does not assume any direct or indirect liability Product modified design changed or parts replaced without URE authorization Changes or attempted repairs and...

Page 12: ...e Energy Co Ltd Page 10 of 12 Warranty Insufficient ventilation of the device The maintenance procedures relating to the product have not been followed to an acceptable standard Force majeure violent or stormy weather lightning overvoltage fire etc Damages caused by any external factors ...

Reviews: