background image

MRX-5

Owner’s Manual

Total Control

MRX-5

Owner’s Manual

Summary of Contents for Total Control MRX-5

Page 1: ...MRX 5 Owner s Manual Total Control MRX 5 Owner s Manual ...

Page 2: ...Panel Descriptions 5 Installing the MRX 5 6 Network Installation 6 Connecting IR Emitters 7 Connecting RS 232 serial 8 Specifications 9 Limited Warranty Statement 9 End User Agreement 11 Federal Communication Commission Interference Statement 12 Technical Support Toll Free 800 904 0800 Main 914 835 4484 techsupport urc automation com Hours 9 00am 6pm EST M F ...

Page 3: ...a streaming devices plays your favorite radio station on your preferred music streaming player and much more The MRX 5 Advanced Network System Controller can ONLY be configured using Total Control software that is ONLY distributed to certified URC integrators Features Benefits Stores the Total Control system s programming single zone including device commands macros events and much more Communicat...

Page 4: ...2 Total Control MRX 5 Owner s Manual Parts List Below is included with MRX 5 ...

Page 5: ...Blinking Blue The device is receiving power but is still initializing Off The device is not receiving power 2 Network LED Indicates three 3 possible states Solid Blue The device is connected to the network and has received an IP address Blinking Blue The device is connected to the network but has not yet received an IP address This LED blinks blue after a Total Control configuration file has been ...

Page 6: ...becomes solid blue when the device has received power 2 IR Outputs Four 4 standard 3 5mm IR emitter ports IR Output 4 provides variable level adjustment 3 RS 232 Port One 1 RS 232 ports support Tx Transmit Rx Receive and GND Ground connections for two way communication Compatible with URC cables RS232F and RS232M 4 USB Port Designed for future use 5 LAN Port RJ45 standard 10 100 Ethernet connectio...

Page 7: ...ss Performs two 2 possible actions Single Tap Power cycle the device Press N Hold Press this button for 15 seconds to restore the device to its factory settings This action cannot be reversed and the device REQUIRES re programming with the Total Control software 2 Mounting Plate Slide the mounting plate up or down to remove it from the device Use the four 4 supplied mounting screws to mount the MR...

Page 8: ...erate local equipment using IP network RS 232 serial IR infrared or relays All cables must be connected to their respective ports at the rear of the device Network Installation 1 Connect an Ethernet cable RJ45 to the rear of the MRX 5 and the onto an available LAN port of the network s local router Luxul preferred 2 A certified URC integrator is required for this step configure the MRX 5 to a DHCP...

Page 9: ...itters four 4 supplied in the box into any of the four 4 IR outputs available on the rear of the MRX 5 IR Output 4 includes an adjustable sensitivity dial Turn this dial to the right to increase the gain and to the left to decrease it 2 Remove the adhesive covering from the emitter and place it over the IR receiver of the 3rd party device cable box television etc 1 2 IR Emitter ...

Page 10: ... Control system Connect RS 232 device using URC s proprietary RS 232 cables These use either male or female DB 9 connections with standard pin outs 1 Connect the 3 5mm into the RS 232 Output available on the MRX 5 2 Connect the Serial connection onto the available port on the 3rd party device such as AVRs Televisions Matrix Switchers and other devices 1 2 3rd Party Device RS 232 Cable ...

Page 11: ...chase by the end user but no longer than forty eight 48 months from the date of shipment of the URC equipment by URC to an authorized URC dealer or distributor This limited warranty is valid only in the United States of America URC equipment purchased from other than an authorized URC dealer or distributor is without warranty URC warrants that the software will substantially conform in any materia...

Page 12: ...ent permitted by applicable law In the event of any warranty claim URC will at its sole option repair the URC equipment using new or comparable rebuilt parts or exchange the URC equipment for new or rebuilt equipment In the event of a defect these are the end user s exclusive remedies All the URC equipment returned for service exchange or repair require an RGA number To obtain an RGA number you mu...

Page 13: ...GRAMS URC S LIABILITY IF ANY FOR DIRECT DAMAGES OF ANY FORM SHALL BE LIMITED TO ACTUAL DAMAGES NOT IN EXCESS OF AMOUNTS PAID BY END USER FOR THE URC EQUIPMENT IN NO EVENT SHALL URC BE LIABLE FOR ANY EVENTS BEYOND ITS CONTROL INCLUDING ANY INSTANCE OF FORCE MAJEURE IN NO EVENT SHALL URC BE LIABLE FOR THE ACTS OR OMISSIONS OF END USER OR ANY THIRD PARTY THE LIMITATIONS OF LIABILITY MAY NOT APPLY TO ...

Page 14: ...technician for help Warning Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment Note The manufacturer is not responsible for any Radio or TV interference caused by unauthorized modifications to this equipment Such modifications could void the user s authority to operate the equipment Note AC DC adaptor which have been approve...

Reviews: