Urban choice UC LOGIC 83AW Installation And Service Instructions Manual Download Page 1

INSTALLATION AND SERVICE INSTRUCTIONS

Keep this booklet for future reference.

The dryer must be fitted by a competent person. In the U.K. Registered Installers undertake to 
work to safe and satisfactory standards. 

The dryer must be installed in accordance with the Gas Safety (Installation and Use) 
Regulations 1998.

Guidance may be obtained from the relevant parts of B.S. 7624: B.S. 5440 parts 1 and 2, B.S. 
6891: current editions, I.E.E. Wiring Regulations, and relevant Building Regulations.

Failure to install the appliance correctly could invalidate the warranty liability claims and could 
lead to prosecution.

FOR USE IN GREAT BRITAIN AND EIRE WITH NATURAL GAS 

ONLY: I

2

H

, GAS SUPPLY PRESSURE : 20 mbar.

THE INSTALLER MUST LEAVE THIS BOOKLET WITH THE 

CUSTOMER

83A

Summary of Contents for UC LOGIC 83AW

Page 1: ...nstallation and Use Regulations 1998 Guidance may be obtained from the relevant parts of B S 7624 B S 5440 parts 1 and 2 B S 6891 current editions I E E Wiring Regulations and relevant Building Regula...

Page 2: ...TIVE LVD 2006 95 EC EN60 335 1 EN60 335 2 11 GAS APPLIANCE DIRECTIVE GAS 90 396 EEC BS 5258 PART 17 1992 EN 1458 1 2000 ELECTROMAGNETIC COMPATIBILITY DIRECTIVE 2004 108 EC EN55014 EN 61000 3 2 EN 6100...

Page 3: ...0 C BURNER Pressed steel with slotted flame perforations Heat input 3 0kW 10235 Btu hr Injector 1 32 mm dia 3 CONTROL Type Pactrol full sequence flame control P16AGTD CE 414601 Ignition electrode gap...

Page 4: ...urniture and similar surfaces 4 VENTING The dryer must be fitted with an exhaust vent hose and the end either hung out of a window or fitted to a wall window vent connection Note Do not obstruct or ad...

Page 5: ...e carried out by a competent person i e registered Engineer 9 STACKING Instructions for stacking if required are supplied with the stacking kit PROGRAMME The electronic control measures dryness by the...

Page 6: ...be removed from the Motor Disconnect the Motor leads Withdraw the black headed pin 537 Exert an anti clockwise force to disconnect the bayonet fitting between the Fan Access Cover 447 and the back of...

Page 7: ...Bearing Assy 270 to the Back Panel 24 Withdraw the 8 screws securing the Back Panel 24 to the Cabinet 196 Disengage the T piece Grommet from the slot in the Back Panel and lift off The Rear Seal 14 ca...

Page 8: ...nnections tight does motor start Check br w wiring from input terminal to door switch Check connections clean and tight does motor start Refer to chart 2 Refer to chart 3 Refer to chart 4 START No No...

Page 9: ...ire with boot Caution the other red wire is live Is voltage between heat selector switch and TB N 230V Exchange both exhaust thermostats 50 C and 60 C and inlet thermostat 130 C brown wires Does contr...

Page 10: ...r light Exchange control unit Does gas light Check continuity of wiring between 4 Way housing and relevant solenoid also neutral wiring Check plug clean and tight Does gas light Fault in gas system re...

Page 11: ...ad suitable Is filter clean Is vent hose or terminal unobstructed Is vent terminal unaffected by wind conditions that may cause back pressure Start No No No No Check gas pressure with all other applia...

Page 12: ...12 ECO 83A...

Page 13: ...403 394 369 196 386 248 370 376 199 11 10 URBAN CHOICE ECO 83A_ EXPLODED VIEW 1 353 352 211 552 377 235 372 213 201 203 232 218 217 219 13 249 556 556 366 365 364 363a 363 203a 359 367 362...

Page 14: ...URBAN CHOICE ECO 83A_ 14 15 16 17 393 375 230 38 389 375 18 375 20 23 21 22 412 375 19 403 396 24 25 26 27 25 14 13 143 398 28 141 408 409 410 411 144 Exploded View 2...

Page 15: ...248 440 442 441 445 446 447 448 356 250 229 406 13 32 29 30 31 456 458 459 445 454 455 URBAN CHOICE ECO 83A_ EXPLODED VIEW 3 15...

Page 16: ...URBAN CHOICE ECO 83A 142 112 101 101a 427 125 16 Exploded View 4 466 477 444 467 465 463 468 464 438 439 266 270 432...

Page 17: ...41 33 482 411 45 31 406 13 32 URBAN CHOICE ECO 83A 375 39 17 Exploded View 5...

Page 18: ...ture Limiter 143 Deg C 4213 092 24151 2 39 Ignition Electrode 4213 092 08491 5 41 M4 x 10 Pan Screw 2522 180 40002 5 45 Solenoid Coil SCEM 4213 092 08501 5 101 Motor and Capacitor Assembly 4213 092 25...

Page 19: ...40003 2 4 403 Roller Assembly 4213 092 35651 1 2 406 M5 Toothed Lockwasher 2513 611 01008 3 407 Hex Nut DC St Zn M5 2522 401 55012 1 2 408 Cable Clamp 2 4213 077 47303 2 409 Washer M5 Form A 2522 604...

Page 20: ...ockwasher 2522 616 15007 5 537 W Button access cover 4213 078 26311 3 552 Knob Extension 4213 077 59953 1 555 Rear Panels Seal Kit 4213 092 28001 2 556 HT Lead 4213 176 00771 1 Bearing Pads Brush Seal...