Page 2: ...e automatically accepted by breaking the security labels on the product 1 PACKAGE CONTENT Inside the package you will find 1 The Unit Modular CPlus 2 One 750 ml bag Optional 1000 ml 3 A window label to indicate the device installation 4 Installation and use manual 2 19 WARNING All UR FOG fogging systems should only be used with UR FOG branded flu ids It is strictly forbidden to use any fluid not p...

Page 3: ...eason you swallow fog fluid or if after contact with eyes or skin you have any kind of reaction and in any case wash it immediately with water and soap Do never stay for a long time in a room filled with fog Do not use charged bags that are not the ones suggested by UR Fog and never try to recharge them they are made for a single use Follow your national rules for the dispose of empty bags Keep UR...

Page 4: ... 5 meters not to let it be reached avoiding possible tampering 15 The unit has a nozzle inclination of 15 oriented to the floor 16 The main body of UR Fog which has the heating system enclosed inside a metal frame should not be opened unless by specific and authorized service centers Do not open and touch for any reason the insulation before 24 hours the unit has been shut off The internal part ma...

Page 5: ... minutes 140 minutes 150 minutes 37 41 W 42 47 W 42 47 W 48 53 W 1 4 A 1 7 A 1 9 A 2 1 A microswitch microswitch microswitch microswitch Yes Yes Yes Yes LAN WIFI board support Yes Yes Yes Yes Yes 16 14 DEFECTS POSSIBLE SOLUTION DEFECT FOUND POSSIBLE CAUSE POSSIBLE SOLUTION Disturbance interference or potential differences between devices In the evenience of high noise on mains power lightings an e...

Page 6: ...to the following parts by skilled operators 1 Verify battery and power supply status 2 Verify screws are firmly closed 3 Verify the output nozzle is not damaged and without anyting inside 4 Verify pneumatic circuit 5 Verify once a year liquid pump BATTERY AND POWER SUPPLY CHECK Verify that the output of the power supply without any load battery unplugged is 14 1 V on the PSU and 13 8 V on FASTON b...

Page 7: ...a qualified technician Connect the equipment to the electricity grid only after you have completed the installation It is necessary to connect the ground terminal The system must be connected to the mains trough on automatic switch automatic switch curie C with Ih 10 A and Idif 30 mA with breching capacity based on the assumed fault current of the fogging system in the sampling point PLEASE NOTE T...

Page 8: ... and will work in parallel with the commands received by the serial interface In no case a voltage greater than the board s power supply should be applied to any pin of this port except for relay outputs that can manage up to 60V 500mA Some interface options depend on S3 Dip Switch configuration and W1 and W2 jumpers Fig 2 shows their position on the board FUNCTION DIP SWITCH fig 1 Tab 1 13 11 INS...

Page 9: ...stem is activated by an event detected by an area or sensor Please note that is ARM costant signal is removed during the shooting the units immediatly stops fog emission Optional shooting methods There are also some other activation methods on Modular Plus series some of them depending also from other optional devices that let the installer able to satisfy the most common customer s requests A Add...

Page 10: ...E MODULAR 3 PLUS max 40 sec m to protect Seconds of emission m to protect Seconds of emission m to protect Seconds of emission 50 150 7 150 450 21 300 900 40 75 225 9 200 600 28 100 300 14 250 750 35 RECOMMENDED SHOOTING SECONDS ACCORDING TO THE VOLUME SPACE TO PROTECT m3 Fogging systems Modular CPlus are able to produce fog continuously till the maximum time allowed according to the model specifi...