MAINTENANCE PROCEDURE
I. Battery Charging Cycle
V
A
15[A]
15 15.3[V]
15.3
Charger off
Time
〔
Hr
〕
T
0
T
1
T
2
0% 75~80% Bat. Cap. 100%
1) At bulk mode from To to T1, approximately 80% of battery capacity is returned.
2) At absorption mode from T1 to T2, approximately 20% of battery capacity is returned.
3) At float mode afterT2, charger is turned off. If the voltage drops due to self-discharge during
storage, the charger will re-start and complete a charge cycle.