UPRENT Betsy 125H User Manual Download Page 1

www.uprent.eu

P U M P I N G   A N D   E N E R G Y   S O L U T I O N S

PUMP

USER

MANUAL

Summary of Contents for Betsy 125H

Page 1: ...www uprent eu P U M P I N G A N D E N E R G Y S O LU T I O N S PUMP USER MANUAL...

Page 2: ...ead 32 mwc see curve Maximal suction lift 8 5m Suction connection 6 Discharge connection 6 Free passage Up to 100mm Dimensions L x W x H 2612mm x 1040mm x 1756mm Weight 1900kg Engine Diesel engine Eng...

Page 3: ......

Page 4: ...1 User manual Betsy 125H...

Page 5: ...p unit 10 5 1 Moving the pump unit with a forklift 11 6 Pump unit installation 12 6 1 Outdoor use 13 6 2 Indoor use 14 7 Daily maintenance of the pump 15 7 2 Priming the fuel system 16 7 3 Engine oil...

Page 6: ...of 8 to 9 meters or a suction length of 70 to 100 meters All pumps are supplied in a sound attenuated version These pumps are ideal for moving sewage water and dirty liquids containing large solids T...

Page 7: ...control box 17 Suction side 18 Check valve 1 3 Intended use Pump are suitable for use in the following sectors contracting rental industry shipping waste water environmental protection water boards ir...

Page 8: ...ot permitted to deploy a standard pump or pump unit in an ATEX environment Use the pump only for those applications listed on the pump specification sheet It is not permitted to use the pump for any a...

Page 9: ...Max head 32 mwc Dimensions L x W x H 2612 x 1040 x 1756 mm Dry weight 1900 kg Fuel tank 300 ltr Solids handling 100 mm Engine Engine brand Deutz Engine type F3L Flywheel power 23 8 kW 32 Hp Max engine...

Page 10: ...7 3 Performance curve...

Page 11: ...and maintained by persons who have received appropriate training and are aware of the associated dangers The installer operator and maintenance personnel must comply with the local safety regulations...

Page 12: ...ting oil B Diesel is hazardous to the environment with substantial remediation costs if it leaks into a drain waterway or the ground C Caution hot surface D Caution crushing danger E Oil F Hazardous o...

Page 13: ...lifting eye on the engine nor the lifting eye of the bare shaft pump may be used for transport of the pump unit WARNING Lifting forces must be as vertical as possible the maximum lifting angle is 15 P...

Page 14: ...d into these pockets to lift the pump unit WARNING Use certified lifting equipment with an adequate lifting capacity and always lift from directly above Lifting from an angle can lead to dangerous sit...

Page 15: ...l Such use results in forfeiture of the right to assert any warranty or damage compensation claims Place the pump unit on a flat surface capable of supporting the load Make sure the pump unit is place...

Page 16: ...can be fitted with safeguards for the following parameters temperature overpressure under pressure direction of rotation oil level overload 6 1 Outdoor use The pump unit is suitable for outdoor use In...

Page 17: ...e area has adequate ventilation Make sure the exhaust gases are discharged outdoors Ensure that there is sufficient free space around the air intake so the engine is able to draw as much air as it nee...

Page 18: ...e glass in the sidewall of the oil reservoir 2 and add if necessary 3 Check the oil level of the engine and add if necessary 3 4 Check the level of the fuel in the fuel tank and add if necessary 5 Che...

Page 19: ...system Prime the fuel system before starting the engine for the first time after the fuel tank has been drained completely or after replacement of the fuel filter s 1 Open the bleeder screw 1 2 Squeez...

Page 20: ...enance engine must be stopped 1 The engine must be in horizontal position before adding oil or checking the oil level 2 Pull out dipstick 4 and add engine oil of the correct specification and viscosit...

Page 21: ...tches 1 2 3 Cable with red marking 1 is Maximum level cable with blue marking is Minimum level but cable in green marking 3 is grounding Installing sensors important is sensor 3 is always under water...

Page 22: ...tic operation 6 Rood red electrode pin position High 7 Blue blue electrode pin position Low 8 Yellow green green and yellow earth electrode pin position Bottom 9 Electrode level socket Note The hour c...

Page 23: ...2 Check the oil levels of the vacuum pump 3 Check the oil level of the engine add if necessary 4 Check the level of the fuel in the fuel tank and add if necessary 5 Check the state and tension of the...

Page 24: ...mp unit Make sure the pump unit can draw adequate fresh air 3 Check whether the prescribed safety provisions are in place 4 Connect the hoses 5 Perform daily maintenance 6 Make sure there is sufficien...

Page 25: ...22 11 Turn the switch 3 H 0 A in the position HAND 12 Turn the throttle 4 to maximum speed 13 Turn the switch 5 to position 1 Engine will start...

Page 26: ...n WARNING If the pump vacuum lift is set too high cavitation in the pump set is possible and this can be recognized by High levels of vibration a crackling noise in the pump decreased capacity and pre...

Page 27: ...ump unit can draw adequate fresh air 3 Check whether the prescribed safety provisions are in place 4 Connect the hoses 5 Perform daily maintenance 6 Make sure there is sufficient fuel in the fuel tank...

Page 28: ...25 12 Turn the switch 3 H 0 A in the position AUTOM 13 Plug automatic level control socket 4 set the minimum an maximum electrodes 14 Turn the throttle 5 to maximum speed...

Page 29: ...a crackling noise in the pump decreased capacity and pressure If this condition is allowed to persist for long periods it will cause damage the pump set Continued running of the pump set in this condi...

Page 30: ...stop 3 Observe whether the system comes to a gradual smooth stop 4 When you suspect that the liquid is beginning to freeze drain the pump while the medium is still in the liquid state 5 Switch off ear...

Page 31: ...g ports covers plugs 1 2 Make sure the canopy draining ports covers plugs 1 are not clogged with solids clean them if clogged 3 Open valves 2 make sure they are not clogged clean it if clogged and dra...

Page 32: ...ient tension on divisible belt vacuum pump Check the tension of the divisible belt vacuum pump Tighten divisible belt with tensioning slide rails vacuum pump Opened drain tap in bottom pump house or f...

Page 33: ...ssible Otherwise use a different type of pump The liquid has a higher s g or viscosity than that for which the pump is intended Change temperature of liquid if possible Otherwise use a different type...

Reviews: