background image

4. Product Performance

UE-12Li75

5. Protective Circuit Specification

The batteries are supplied with a LiFePO4 Battery Management System (BMS) that can monitor and optimized 
each single prismatic cell during charge & discharge, to protect the battery pack overcharge, over discharge, 
short circuit. Overall, the BMS helps to ensure safe and accurate running.

NO.

Items

Minimum Capacity

2

3

-20°C

Testing Method

Rated Capacity 

1

75Ah

Criteria

Rest for 1 hour after fully charged, then discharge 
with 0.33C current until the battery reaches the 
discharge cutoff voltage. Repeat above process for 
three times, if the discharge time is not less than 120 
minutes, you can stop and define the Discharging 
current*time value (Ah) as battery capacity.  

71.25Ah

Discharge 
Temperature 
Characteristics

At 25±5°C discharge the battery with the current of 
0.33C to the cut-off voltage and record charge 
capacity. Store the battery at various temperatures 
for 2h and discharge the battery with 0.33C to the 
cut-off voltage.

0°C

25°C

55°C

≥70%

≥80%

≥100%

≥95%

Charge the battery to full capacity and store it for 28 
days, and then discharge it with 0.33C to the cut-off 
voltage.

Charge Retention 
ability

Residual 
capacity ≥80%

Internal resistance

≤30mΩ

50% battery SOC state frequency of 1 KHZ ac resistan-
ce tester.

Discharge with the current of 0.33C until it can’t 
discharge, and then rest it for 1h. Charge the battery 
following CC (0.33C)/CV (14.6V) mode to full capacity, 
and then rest it for 1h. Repeat above process until full 
charged capacity is no more than 80% of normal 
value. Accumulated times is defined as cycle life.

4

Cycle life (DOD%100)

≥2500 cycles

5

6

Recovery 
capacity ≥90%

01

01

01

03

www.upowerbatteries.com

66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
[email protected]

Reviews: