background image

INSTRUCTION SheeT

The Boiler Relay (A9012010) is 
used on any boiler or heating device 
requiring a dry-contact input to start 
the heat demand. This control is 
compatible with the Uponor Climate 
Co˘ntrol™ Multifunction unit and 
Uponor Climate Co˘ntrol™ Controller 
Network System.

The Boiler Relay contains two dry 
contacts (labeled “A” and “B” terminals):
•  The “A” terminal is always used to 

start the heating device.

•  The “B” terminal can be used in  

two ways:

•  To provide a high temperature 

override or domestic hot water 

•  To start the second stage of 

boiler with a two-stage  
firing control

Getting Started

Check the contents of this package. 
If the contents are damaged, please 
contact your Uponor sales representative 
or distributor for assistance.

The package includes:
• Network Boiler Relay (A9012010)

Tools and Parts Required

• RJ45 crimper and connectors
• Cable tester
• Wire cutter and stripper
• Small-blade screwdriver

Installation

Mounting the Unit

Mount the relay control directly to a 
boiler (see 

Figure 1

) or a separate 

electrical box using a standard ½-inch 
conduit hub (see 

Figure 2

).

Figure 1: Boiler Mounting

Figure 2: electrical Box 

Mounting

  Caution:

 Before performing 

any wiring, disconnect the 
electrical power to the 
system to prevent electrical 
shock and damage to  
the device.

Note:

  Ensure all wiring complies with 

local electrical codes.

Communication Cable

The Boiler Relay connects a heating 
device to the operating control via a 
single RJ45-terminated Cat5e cable. 
The boiler relay control can be used 
on either of the Uponor control 
systems, Multifunction or Network, 
as follows.

•  Uponor Climate C˘ontrol 

Multifunction Controller 

The boiler relay controls connect 
to Ports 1 and 2 (only) on the right 
side of the Multifunction control.

•  Uponor Climate C˘ontrol 

Network System

 

The boiler relay controls connect to 
TT ports 1 through 5 on the right 
side of the Primary Equipment 
Control (A9012000).

Refer to Appendix D in the Uponor 
Climate C˘ontrol Network System 
Manual for more information about 
making Cat5e patch cables.

Network Boiler Relay

R A D I A N T   h E A T I N g   S y S T E M S

U P O N O R   C l I M a T e   

C O

˘

N T R O l ™   N e T w O R k   

S y S T e M   B O I l e R   R e l a y